LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #636 • Municipal • PJM

City of Anderson - (IN) (IN) Outage & Grid Reliability

City of Anderson - (IN) (U.S. EIA Utility #636, Municipal) serves 33,543 total customers across 1 county/counties in Indiana (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1376.2 outage minutes per year (22.9 hours, SAIDI with major events) across 3 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 12.67¢/kWh.

EIA Outage Time (SAIDI)1376.2 min/yr (22.9 hrs)
Reliability GradeGrade CCC
Customers Served33,543 Total
Avg Residential Rate12.67¢/kWh
Utility Reliability Summary (City of Anderson - (IN)): City of Anderson - (IN) (U.S. EIA Utility #636, Municipal) serves 33,543 total customers across 1 county/counties in Indiana (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1376.2 outage minutes per year (22.9 hours, SAIDI with major events) across 3 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 12.67¢/kWh.
Utility Reliability Field Brief • City of Anderson - (IN) (IN)

What City of Anderson - (IN) Outage Data Means for Customers

City of Anderson - (IN) is a municipal utility in the PJM balancing authority, serving 33,543 customers in Madison County: 29,600 residential, 3,886 commercial, and 57 industrial. The EIA Form 861 numbers tell two stories. Without major events, the average customer loses power for 264.1 minutes a year, a little over four hours. With major events included, SAIDI jumps to 1376.2 minutes, roughly 23 hours. SAIFI is 3.0 interruptions per year. That gap is the lesson. Most years you get a few blinks and short outages, but a bad storm year can run for days. EP grades this territory CCC, severe multi-day outage territory, so plan for the bad year, not the average one. At 12.67 cents per kWh residential, grid power is your cheap option. Backup is insurance, not a savings plan.

Sizing Quiet Home Backup vs. Standby Power in IN

Start with a written list of what must keep running: refrigerator, furnace blower, sump pump, well pump if you have one, a few lights, internet, and any medical equipment. Add up the running watts, then allow for motor startup surge, because pumps and compressors pull far more for a moment than they do running.

A battery system is quiet, has no exhaust, and suits the three-interruptions-a-year pattern well. It carries essentials through short outages without you touching anything. In a multi-day event, though, a battery runs dry unless solar recharges it or a generator backs it up.

A natural gas or propane standby generator handles long outages and bigger loads, but it needs a transfer switch, proper permits, a licensed electrician, correct clearances from windows and doors, and regular exercise runs. Pairing a modest battery with a standby generator is often the sensible answer for a CCC-grade territory.

If you use a portable generator, keep it outdoors and well away from the house. Never backfeed through a dryer outlet. Carbon monoxide kills people every storm season.

What Local Shops, Clinics & Facilities on City of Anderson - (IN) Lines Should Do

Make a critical-load list before you buy anything. For shops, that means refrigeration, point-of-sale, phones, network gear, egress lighting, and enough HVAC to stay open. For clinics, add medication and vaccine refrigeration, records access, and any powered patient equipment. Put a UPS on IT and communications so a blink does not become a reboot. Put life-safety and refrigeration loads on a generator with an automatic transfer switch.

Test under real load, not just idle. Log fuel, change filters, and service the unit on schedule. A generator that has never carried the building is a guess. Ask your installer about emissions and permitting requirements, including U.S. EPA rules for stationary engines.

Municipal operators should rank water, wastewater lift stations, communications, and traffic control, then confirm run-time against a realistic multi-day outage with a fuel delivery plan in writing.

The 57 industrial customers should note that three interruptions a year can trip drives and controls even when the outage is short. Ride-through protection on sensitive process equipment pays for itself. Keep your own outage log with dates and durations, and ask the utility for feeder-level history so your sizing rests on your circuit, not the system average.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)1376.2 min/yr (22.9 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)3 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)458.7 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)264.1 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)33,543 (29,600 / 3,886 / 57)2025 EIA Form 861
Observed Residential Electricity Rate12.67¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityMunicipal • PJMU.S. EIA Form 861

2. Counties Served by City of Anderson - (IN) (1 Tracked in Indiana)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (City of Anderson - (IN))

How reliable is City of Anderson - (IN) compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, City of Anderson - (IN) logged 1376.2 total outage minutes/year (SAIDI with Major Event Days) and 264.1 minutes/year excluding major storms (Severe Multi-Day Outage Territory (>20 hrs/yr)).

What counties does City of Anderson - (IN) serve in Indiana?

U.S. EIA Form 861 Service Territory records map City of Anderson - (IN) to Madison County in Indiana.

What backup battery or generator size is recommended for City of Anderson - (IN) customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power