LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #60482 • Cooperative • SWPP

CKenergy Electric Cooperative (OK) Outage & Grid Reliability

CKenergy Electric Cooperative (U.S. EIA Utility #60482, Cooperative) serves 27,723 total customers across 9 county/counties in Oklahoma (SWPP grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 498.4 outage minutes per year (8.3 hours, SAIDI with major events) across 4.68 interruptions/yr — earning an EP Utility Reliability Grade of BB. Observed average residential rate: 13.84¢/kWh.

EIA Outage Time (SAIDI)498.4 min/yr (8.3 hrs)
Reliability GradeGrade BB
Customers Served27,723 Total
Avg Residential Rate13.84¢/kWh
Utility Reliability Summary (CKenergy Electric Cooperative): CKenergy Electric Cooperative (U.S. EIA Utility #60482, Cooperative) serves 27,723 total customers across 9 county/counties in Oklahoma (SWPP grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 498.4 outage minutes per year (8.3 hours, SAIDI with major events) across 4.68 interruptions/yr — earning an EP Utility Reliability Grade of BB. Observed average residential rate: 13.84¢/kWh.
Utility Reliability Field Brief • CKenergy Electric Cooperative (OK)

What CKenergy Electric Cooperative Outage Data Means for Customers

CKenergy is a cooperative in the SWPP balancing authority, serving 27,723 customers: 22,775 residential, 4,912 commercial, and 36 industrial. The 2025 EIA Form 861 shows SAIDI at 498.4 minutes a year with major events and 498.2 without them. SAIFI is 4.68 outages a year.

In plain terms, the average member is dark for roughly 8 hours a year, spread over nearly five interruptions. That fits the BB grade, which means elevated multi-hour outage territory at 7 to 12 hours a year. The gap between 498.4 and 498.2 is two-tenths of a minute, so big storms are not what drives this number. Ordinary faults on ordinary days are. Plan for frequent outages, not a once-a-decade event.

Averages hide a lot. If you sit at the end of a long rural tap in Blaine, Caddo, Canadian, Comanche, Custer, or Dewey County, your experience can run worse than the system figure. At 13.84 cents per kWh residential, grid power is not the problem. Reliability is.

Sizing Quiet Home Backup vs. Standby Power in OK

Start with how you get hit. Nearly five interruptions a year means many short events, and a battery system handles those without noise, fuel, or fuss. Size it to the loads you cannot live without: refrigerator, freezer, lights, router, phone chargers, medical devices, and a sump pump if you have one. Add up running watts, then check the surge rating for anything with a motor.

If you have a well pump, central air, or electric heat, batteries get expensive fast. A standby generator on a properly installed transfer switch carries those loads through a long outage, as long as you keep fuel supplied. Many homes do best with both: a small battery for the blips and a generator for the long ones.

Hire a licensed electrician. Never backfeed a house through a dryer outlet, because that kills line crews. Run portable generators outdoors, well away from doors and windows, because carbon monoxide takes people every year. Look for U.S. EPA-compliant units and test them under real load, not just by letting them idle.

What Local Shops, Clinics & Facilities on CKenergy Electric Cooperative Lines Should Do

Write down what must stay running and what can wait. For a shop, that usually means coolers, point of sale, network gear, phones, and egress lighting. For a clinic, it means medication and vaccine refrigeration, records access, and critical equipment. Put those loads on a dedicated emergency panel instead of trying to back up the whole building.

Municipal operators should start with water plants, lift stations, dispatch, and fuel pumps. Exercise each generator monthly under load, log the results, rotate fuel, and keep spare filters and batteries on the shelf. A generator that has never carried the load is a guess, not a plan.

Industrial members, all 36 of you, should protect controls and drives with ride-through equipment so a blink does not become a lost shift. Everyone should call the cooperative, ask about outage history on your specific feeder, and keep a log of your own outages. Your records plus the BB grade give you the evidence to size backup correctly and to press for fixes on your line.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)498.4 min/yr (8.3 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)4.68 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)106.5 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)498.2 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)27,723 (22,775 / 4,912 / 36)2025 EIA Form 861
Observed Residential Electricity Rate13.84¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • SWPPU.S. EIA Form 861

2. Counties Served by CKenergy Electric Cooperative (9 Tracked in Oklahoma)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (CKenergy Electric Cooperative)

How reliable is CKenergy Electric Cooperative compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, CKenergy Electric Cooperative logged 498.4 total outage minutes/year (SAIDI with Major Event Days) and 498.2 minutes/year excluding major storms (Elevated Multi-Hour Outage Territory (7–12 hrs/yr)).

What counties does CKenergy Electric Cooperative serve in Oklahoma?

U.S. EIA Form 861 Service Territory records map CKenergy Electric Cooperative to Blaine County, Caddo County, Canadian County, Comanche County, Custer County, Dewey County, Grady County, Kiowa County and 1 additional counties in Oklahoma.

What backup battery or generator size is recommended for CKenergy Electric Cooperative customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power