LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #4176 • Investor Owned • ISNE

Connecticut Light & Power Co (CT) Outage & Grid Reliability

Connecticut Light & Power Co (U.S. EIA Utility #4176, Investor Owned) serves 1,309,946 total customers across 1 county/counties in Connecticut (ISNE grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 216.6 outage minutes per year (3.6 hours, SAIDI with major events) across 1 interruptions/yr — earning an EP Utility Reliability Grade of A. Observed average residential rate: 26.8¢/kWh.

EIA Outage Time (SAIDI)216.6 min/yr (3.6 hrs)
Reliability GradeGrade A
Customers Served1,309,946 Total
Avg Residential Rate26.8¢/kWh
Utility Reliability Summary (Connecticut Light & Power Co): Connecticut Light & Power Co (U.S. EIA Utility #4176, Investor Owned) serves 1,309,946 total customers across 1 county/counties in Connecticut (ISNE grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 216.6 outage minutes per year (3.6 hours, SAIDI with major events) across 1 interruptions/yr — earning an EP Utility Reliability Grade of A. Observed average residential rate: 26.8¢/kWh.
Utility Reliability Field Brief • Connecticut Light & Power Co (CT)

What Connecticut Light & Power Co Outage Data Means for Customers

Connecticut Light & Power Co is an investor-owned utility in the ISNE balancing area, serving 1,309,946 customers: 1,193,581 residential, 113,578 commercial, and 2,785 industrial. The 2025 EIA Form 861 shows SAIDI of 216.6 minutes per year with major events and 85.4 minutes without them. SAIFI is 1.0 outages per year. That earns an A grade, since anything at or under 260 minutes counts as above-average reliability.

Here is how I read it. On a normal year, the average customer loses power about once and is back in under an hour and a half. The gap between 85.4 and 216.6 minutes, about 131 minutes, comes from major events like storms. Averages hide the tail. Your own feeder, a tree-lined rural road, or the end of a long overhead line can run well worse than the system number. Most of the pain comes from the one bad storm, not the routine blink. Plan for that storm, not the average.

Sizing Quiet Home Backup vs. Standby Power in CT

Start with a list of what must stay on: refrigerator, furnace blower or boiler controls, well pump if you have one, sump pump, lights, internet, phone charging, and any medical equipment. Add up the running watts, then check the startup surge on motors. Most sizing mistakes come from skipping the surge.

A battery system is quiet, has no exhaust, and rides through the short outages that make up much of the 1.0 outages per year. It suits a tight critical-loads panel. It will not carry electric heat, a dryer, or central air for long, and it will not outlast a multi-day storm unless solar recharges it.

A permanent standby generator on natural gas or propane handles long outages and heavy loads. It needs a properly permitted transfer switch, correct clearances from windows and openings, and a maintenance schedule. Exercise it, change the oil, and check engine emissions requirements under U.S. EPA rules.

At 26.8 cents per kWh residential, grid power is not cheap, but backup should be bought for resilience, not savings. Never backfeed a house through a dryer outlet. It kills line crews.

For most homes, a battery covers the routine outage and a standby unit covers the storm week. Pick based on how long your road stays dark, not on the averages.

What Local Shops, Clinics & Facilities on Connecticut Light & Power Co Lines Should Do

With 113,578 commercial and 2,785 industrial accounts on the system, plenty of you share feeders with homes, and restoration follows the utility's priorities, not yours. Do not assume you will be first back.

Begin with a load study. Separate life-safety and legally required loads from nice-to-have loads. Cold storage, vaccine refrigeration, point-of-sale, network gear, egress lighting, and critical HVAC come first. Put them on dedicated panels so a transfer switch moves only what you need.

Protect electronics with an uninterruptible power supply, sized to bridge the seconds before a generator picks up. Test the generator under real load, not just idle, and keep a log. Many failures are dead starting batteries, stale fuel, or a transfer switch nobody has exercised.

Municipal operators should treat water, wastewater, dispatch, and shelter facilities as first-tier backup candidates. Confirm fuel supply contracts and refueling plans before the storm. If your site must run for days, have a plan for refueling and a manual fallback.

Last, talk to your utility account representative about your feeder's outage history. The A grade is a good sign, but your own site's record is what should drive the spend.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)216.6 min/yr (3.6 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)215.5 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)85.4 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)1,309,946 (1,193,581 / 113,578 / 2,785)2025 EIA Form 861
Observed Residential Electricity Rate26.8¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityInvestor Owned • ISNEU.S. EIA Form 861

3. Frequently Asked Questions (Connecticut Light & Power Co)

How reliable is Connecticut Light & Power Co compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Connecticut Light & Power Co logged 216.6 total outage minutes/year (SAIDI with Major Event Days) and 85.4 minutes/year excluding major storms (Above-Average Reliability (<=260 min/yr)).

What counties does Connecticut Light & Power Co serve in Connecticut?

Connecticut Light & Power Co operates within Connecticut (Investor Owned). Check your exact county dossier via the Connecticut State Command Hub.

What backup battery or generator size is recommended for Connecticut Light & Power Co customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power