LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #12796 • Investor Owned • PJM

Monongahela Power Co (WV) Outage & Grid Reliability

Monongahela Power Co (U.S. EIA Utility #12796, Investor Owned) serves 397,362 total customers across 34 county/counties in West Virginia (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1250.4 outage minutes per year (20.8 hours, SAIDI with major events) across 3.72 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 14.31¢/kWh.

EIA Outage Time (SAIDI)1250.4 min/yr (20.8 hrs)
Reliability GradeGrade CCC
Customers Served397,362 Total
Avg Residential Rate14.31¢/kWh
Utility Reliability Summary (Monongahela Power Co): Monongahela Power Co (U.S. EIA Utility #12796, Investor Owned) serves 397,362 total customers across 34 county/counties in West Virginia (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1250.4 outage minutes per year (20.8 hours, SAIDI with major events) across 3.72 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 14.31¢/kWh.
Utility Reliability Field Brief • Monongahela Power Co (WV)

What Monongahela Power Co Outage Data Means for Customers

Monongahela Power Co is an investor-owned utility in the PJM balancing authority, serving 397,362 customers: 334,336 residential, 56,676 commercial, and 6,350 industrial. The 2025 EIA Form 861 numbers show 1250.4 minutes of interruption per customer per year with major events included, just under 21 hours, spread across 3.72 outages. Take the major events out and it drops to 553.3 minutes, about 9 hours. That gap of roughly 11 to 12 hours is storm damage, the trees and broken poles that take days to clear in rural hollows.

EP grades this territory CCC, severe multi-day outage territory. If you live in places like Barbour, Braxton, Calhoun, Clay, or Doddridge County, plan for the long outage, not just the flicker. At 14.31 cents per kWh residential, the grid is not the expensive part. Being dark for three days is.

Sizing Quiet Home Backup vs. Standby Power in WV

Start with what you must keep running: refrigerator, freezer, a few lights, internet, phone chargers, the furnace blower, and a sump or well pump if you have one. Write down the running watts and the startup surge of each. Well pumps and compressors surge hard, and that surge is what undersizes most systems.

A battery and inverter system is quiet, has no fumes, and handles the short outages that make up much of that 3.72 a year. It works well for essentials. Its weakness is a multi-day storm, when it needs solar or a generator to recharge. A permanently installed standby generator on natural gas or propane carries the whole house through a long event, as long as fuel keeps flowing.

Either way, have a licensed electrician do the load calculation and install a transfer switch or interlock. Never backfeed through a dryer outlet, because that kills line crews. Run any engine outdoors, well away from windows, with a working carbon monoxide alarm inside.

What Local Shops, Clinics & Facilities on Monongahela Power Co Lines Should Do

Pick your critical loads before the storm, not during it. For a shop, that usually means refrigeration, point of sale, phones, and egress lighting. For a clinic, it means medication refrigeration, records access, and the equipment your patients depend on. For municipal operators, it means water treatment, sewer lift stations, and communications. Put those circuits on a dedicated backup panel so you are not sizing a generator for the whole building.

Use a UPS for computers and network gear so the generator has time to start. Test the generator under real load every month, not just a no-load run, and log it. Keep a fuel supply plan and a refueling contract, because a generator that runs dry on day two is a very expensive paperweight.

Industrial customers should talk with their utility account representative about feeder history and restoration priorities. With a CCC grade, assume your outage will outlast your fuel unless you plan otherwise.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)1250.4 min/yr (20.8 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)3.72 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)336.3 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)553.3 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)397,362 (334,336 / 56,676 / 6,350)2025 EIA Form 861
Observed Residential Electricity Rate14.31¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityInvestor Owned • PJMU.S. EIA Form 861

2. Counties Served by Monongahela Power Co (34 Tracked in West Virginia)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Monongahela Power Co)

How reliable is Monongahela Power Co compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Monongahela Power Co logged 1250.4 total outage minutes/year (SAIDI with Major Event Days) and 553.3 minutes/year excluding major storms (Severe Multi-Day Outage Territory (>20 hrs/yr)).

What counties does Monongahela Power Co serve in West Virginia?

U.S. EIA Form 861 Service Territory records map Monongahela Power Co to Barbour County, Braxton County, Brooke County, Calhoun County, Clay County, Doddridge County, Gilmer County, Grant County and 26 additional counties in West Virginia.

What backup battery or generator size is recommended for Monongahela Power Co customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power