U.S. EIA Form 861 Utility Profile • Utility #14006 • Investor Owned • PJM

Ohio Power Co (OH) Outage & Grid Reliability

Ohio Power Co (U.S. EIA Utility #14006, Investor Owned) serves 1,543,033 total customers across 53 county/counties in Ohio (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 220.7 outage minutes per year (3.7 hours, SAIDI with major events) across 1.22 interruptions/yr — earning an EP Utility Reliability Grade of A. Observed average residential rate: 13.9¢/kWh.

EIA Outage Time (SAIDI)220.7 min/yr (3.7 hrs)
Reliability GradeGrade A
Customers Served1,543,033 Total
Avg Residential Rate13.9¢/kWh
Utility Reliability Summary (Ohio Power Co): Ohio Power Co (U.S. EIA Utility #14006, Investor Owned) serves 1,543,033 total customers across 53 county/counties in Ohio (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 220.7 outage minutes per year (3.7 hours, SAIDI with major events) across 1.22 interruptions/yr — earning an EP Utility Reliability Grade of A. Observed average residential rate: 13.9¢/kWh.
Utility Reliability Field Brief • Ohio Power Co (OH)

What Ohio Power Co Outage Data Means for Customers

Ohio Power Co is an investor-owned utility in the PJM balancing authority. It serves 1,543,033 customers: 1,348,588 residential, 185,877 commercial, and 8,568 industrial. The 2025 EIA Form 861 shows 220.7 minutes per year of outage time with major events included, and 145.2 minutes without them. That puts the utility in our Grade A band, which covers anything at or under 260 minutes. The gap of roughly 75 minutes between the two numbers is mostly storm damage: wind, ice, and trees in conductors.

SAIFI is 1.22, so the average customer sees a bit more than one interruption a year. These are system averages, though. If you sit at the end of a long rural feeder in a county like Adams, Athens, or Belmont, you can have a very different year than someone in a dense part of town near a substation. Averages also hide the one bad storm that leaves a neighborhood dark for days. Grade A means the grid is good. It does not mean your circuit is.

Sizing Quiet Home Backup vs. Standby Power in OH

Start with what has to keep running: refrigerator, sump pump, furnace blower, a few lights, internet, and any medical equipment. Add up the running watts, then check the starting surge on anything with a motor. Sump pumps, well pumps, and air conditioners draw far more for a moment than they do running. Size to that surge, not the nameplate average.

With average outages this modest, a battery system sized for essential circuits often covers the typical event quietly, with no fuel and no fumes. It makes the most sense if you have a short list of critical loads. If you have a well, electric heat, or a long storm-season outage history on your feeder, a permanently installed standby generator on natural gas or propane gives you duration that batteries can't. Pairing a modest battery with a generator is a sound approach for some homes.

Whatever you choose, use a transfer switch installed by a licensed electrician. Never backfeed through a dryer outlet, because that kills line crews. Run portable generators outdoors, well away from windows, and keep a working carbon monoxide alarm inside. Look for engines that meet U.S. EPA requirements. At 13.9 cents per kWh residential, grid power is cheap compared with generator fuel, so use backup for outages, not for saving money.

What Local Shops, Clinics & Facilities on Ohio Power Co Lines Should Do

Convert outage minutes into dollars. Spoiled inventory, lost sales, and idle staff set your real backup budget, not the utility's reliability grade. List your loads in three tiers: life-safety and data, revenue-critical, and nice-to-have. Back up the first two tiers only.

Clinics and care facilities should confirm which circuits are on the emergency system, test under actual load, and keep fuel on hand and rotated. A generator that starts with no load but trips under real demand is common, so exercise it monthly and run a load test each year. Retail and food businesses should protect refrigeration, point-of-sale, and network gear first. A small UPS for the network and POS equipment often prevents more losses than a big generator would.

Municipal operators should treat water, wastewater, traffic signals, and dispatch as the priority loads. Set up automatic transfer, document fuel logistics, and talk with your Ohio Power Co account contact about circuit priority and sectionalizing. Customers in counties such as Allen, Ashland, and Auglaize can ask which feeder serves them and how it has performed during recent storms. Finally, write down who flips what and when, because the plan fails if only one person knows it.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)220.7 min/yr (3.7 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.22 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)180.5 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)145.2 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)1,543,033 (1,348,588 / 185,877 / 8,568)2025 EIA Form 861
Observed Residential Electricity Rate13.9¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityInvestor Owned • PJMU.S. EIA Form 861

2. Counties Served by Ohio Power Co (53 Tracked in Ohio)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Ohio Power Co)

How reliable is Ohio Power Co compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Ohio Power Co logged 220.7 total outage minutes/year (SAIDI with Major Event Days) and 145.2 minutes/year excluding major storms (Above-Average Reliability (<=260 min/yr)).

What counties does Ohio Power Co serve in Ohio?

U.S. EIA Form 861 Service Territory records map Ohio Power Co to Adams County, Allen County, Ashland County, Athens County, Auglaize County, Belmont County, Carroll County, Columbiana County and 45 additional counties in Ohio.

What backup battery or generator size is recommended for Ohio Power Co customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power