LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #15477 • Investor Owned • PJM

Public Service Elec & Gas Co (NJ) Outage & Grid Reliability

Public Service Elec & Gas Co (U.S. EIA Utility #15477, Investor Owned) serves 2,405,805 total customers across 14 county/counties in New Jersey (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 66.2 outage minutes per year (1.1 hours, SAIDI with major events) across 0.72 interruptions/yr — earning an EP Utility Reliability Grade of AAA. Observed average residential rate: 24.25¢/kWh.

EIA Outage Time (SAIDI)66.2 min/yr (1.1 hrs)
Reliability GradeGrade AAA
Customers Served2,405,805 Total
Avg Residential Rate24.25¢/kWh
Utility Reliability Summary (Public Service Elec & Gas Co): Public Service Elec & Gas Co (U.S. EIA Utility #15477, Investor Owned) serves 2,405,805 total customers across 14 county/counties in New Jersey (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 66.2 outage minutes per year (1.1 hours, SAIDI with major events) across 0.72 interruptions/yr — earning an EP Utility Reliability Grade of AAA. Observed average residential rate: 24.25¢/kWh.
Utility Reliability Field Brief • Public Service Elec & Gas Co (NJ)

What Public Service Elec & Gas Co Outage Data Means for Customers

Public Service Elec & Gas Co is an investor-owned utility in the PJM balancing authority. It serves 2,405,805 customers in New Jersey: 2,072,339 residential, 325,250 commercial, and 8,210 industrial. Tracked counties include Bergen, Burlington, Camden, Essex, Gloucester, and Hudson.

The 2025 EIA Form 861 numbers are good. SAIDI is 66.2 minutes a year with major events and 42.6 without them. SAIFI is 0.72 outages a year. In plain terms, the average customer loses power less than once a year, and the typical year adds up to about an hour. Divide 66.2 by 0.72 and you get roughly 92 minutes per interruption. The EP Utility Grid Reliability Grade is AAA, top decile.

Averages hide the tail, though. The gap of about 24 minutes between the two SAIDI figures is storm damage. If you sit at the end of a long feeder, under old trees, or in a flood-prone basement, your experience can be much worse than the average. Plan backup for your bad day, not the utility's average day.

Sizing Quiet Home Backup vs. Standby Power in NJ

Start with a list of what you actually need: refrigerator, lights, internet router, phone chargers, sump pump, furnace blower, and any medical equipment. Write down the running watts for each, then check the starting surge on anything with a motor. Surge is what trips undersized units.

A home battery system fits the short outage. It is silent, can run indoors-adjacent, and handles the ordinary event of an hour or two. At 24.25 cents per kWh, don't expect it to pay for itself through rate games. Buy it for the outage.

A standby generator makes sense if you need days of coverage, run medical equipment, or want to carry heavier loads like central air. It has to be installed with a permanent transfer switch by a licensed electrician, with a permit. Never backfeed through a dryer outlet. Portable units run outdoors only, well away from windows, with working carbon monoxide alarms inside. Mount equipment above any known flood line.

A sensible middle path is a battery for critical circuits, with a generator input for the rare multi-day event.

What Local Shops, Clinics & Facilities on Public Service Elec & Gas Co Lines Should Do

With about 92 minutes per typical interruption, the first job is ride-through. Put a UPS on point-of-sale systems, servers, network gear, and phones so nothing corrupts or reboots. Then decide what must stay alive past the first couple of hours: refrigeration, emergency lighting, door access, and life-safety systems.

Clinics should treat medication and vaccine refrigeration as the top-priority load, with temperature logs and a written plan for moving stock. Shops with coolers or freezers should know how long product holds temperature with the doors shut.

Municipal operators should rank loads in tiers: communications and dispatch, pump stations, traffic signals at key intersections, then shelters and office space. Every generator needs a monthly run under real load, an annual service, and a fuel plan that does not depend on one supplier. Check air permit and U.S. EPA engine emissions requirements before you buy, not after.

Whatever your size, test the transfer. A generator that has never carried the building is a guess, not a plan.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)66.2 min/yr (1.1 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)0.72 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)92 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)42.6 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)2,405,805 (2,072,339 / 325,250 / 8,210)2025 EIA Form 861
Observed Residential Electricity Rate24.25¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityInvestor Owned • PJMU.S. EIA Form 861

2. Counties Served by Public Service Elec & Gas Co (14 Tracked in New Jersey)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Public Service Elec & Gas Co)

How reliable is Public Service Elec & Gas Co compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Public Service Elec & Gas Co logged 66.2 total outage minutes/year (SAIDI with Major Event Days) and 42.6 minutes/year excluding major storms (Top-Decile Grid Reliability (<=90 min/yr)).

What counties does Public Service Elec & Gas Co serve in New Jersey?

U.S. EIA Form 861 Service Territory records map Public Service Elec & Gas Co to Bergen County, Burlington County, Camden County, Essex County, Gloucester County, Hudson County, Mercer County, Middlesex County and 6 additional counties in New Jersey.

What backup battery or generator size is recommended for Public Service Elec & Gas Co customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power