PUD No 1 of Franklin County (WA) Outage & Grid Reliability
PUD No 1 of Franklin County (U.S. EIA Utility #6716, Political Subdivision) serves 30,076 total customers across 1 county/counties in Washington (BPAT grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 90.6 outage minutes per year (1.5 hours, SAIDI with major events) across 0.6 interruptions/yr — earning an EP Utility Reliability Grade of AA. Observed average residential rate: 9.99¢/kWh.
What PUD No 1 of Franklin County Outage Data Means for Customers
PUD No 1 of Franklin County is a political subdivision, a locally governed public utility serving 30,076 customers: 27,692 residential, 2,050 commercial, and 334 industrial. It operates in the BPAT balancing authority. The 2025 EIA Form 861 numbers are good. SAIDI with major events is 90.6 minutes a year, SAIFI is 0.6 interruptions a year, and SAIDI without major events is 42.0 minutes. That earns an AA grade, high reliability, in the 160-minutes-or-less class.
Here is what that means at the kitchen table. The average customer loses power less than once a year, and dividing 90.6 by 0.6 gives roughly 150 minutes per interruption, about two and a half hours. Averages hide the tail, though. The gap between 42.0 and 90.6 minutes is major-event time, and that is when outages run long. A home at the end of a long feeder can do worse than the system average. Residential power averages 9.99 cents per kWh, so grid electricity is cheap. Backup power is insurance, not savings.
Sizing Quiet Home Backup vs. Standby Power in WA
With outages short and infrequent, most homes do not need a whole-house generator. Start with what must stay on: refrigerator, freezer, furnace blower, well pump if you have one, router, lights, phone charging, and any medical equipment. Add up the running watts, then check the starting surge on motors. A battery and inverter system handles that short list quietly through a typical outage and switches over without a gap. If someone depends on oxygen or another powered device, size for a much longer outage than the average, because the average is not a promise.
A natural gas or propane standby generator makes sense for all-electric homes, long storm events, or temperature extremes. Have a licensed electrician install a proper transfer switch. Never backfeed a house through a dryer outlet. Keep units well away from windows and doors because of carbon monoxide, follow local permit rules, and run the engine monthly. Check the label for U.S. EPA emissions certification. A portable generator is fine if you have an interlock or inlet installed and fuel stored safely.
What Local Shops, Clinics & Facilities on PUD No 1 of Franklin County Lines Should Do
Your number is not the system average. It is your cost per hour of downtime. Walk your panel and sort loads into life safety, critical process, and nice-to-have. A small shop may only need a UPS for registers and network gear, plus a generator inlet feeding a few circuits. Cold storage for food or medicine deserves a temperature monitor that texts a human at 2 a.m.
Clinics and municipal operators should document critical loads, test transfer switches under real load, and rotate stored fuel. Run an actual outage drill every year. Most failures are dead starting batteries, tripped breakers, and nobody knowing where the key is. Ask the PUD about your feeder's outage history and planned work, and whether it keeps a critical-facility list. Industrial users should also plan for voltage sags, which can stop a process without ever showing up in SAIDI.
1. Official U.S. EIA Form 861 Reliability & Customer Record
| EIA Form 861 Metric | Observed Utility Value | Reporting Basis |
|---|---|---|
| SAIDI (Total Outage Minutes / Year) | 90.6 min/yr (1.5 hrs) | All Events w/ Major Event Days (2025) |
| SAIFI (Average Outages / Year) | 0.6 interruptions/yr | IEEE / Utility Standard w/ MED |
| CAIDI (Avg Restoration Minutes / Outage) | 151.5 min/outage | Average Customer Outage Duration |
| SAIDI (Blue-Sky / Excluding Major Storms) | 42 min/yr | Without Major Event Days |
| Total Customers (Res / Com / Ind) | 30,076 (27,692 / 2,050 / 334) | 2025 EIA Form 861 |
| Observed Residential Electricity Rate | 9.99¢/kWh | 2025 EIA Revenues / MWh |
| Ownership & Balancing Authority | Political Subdivision • BPAT | U.S. EIA Form 861 |
2. Counties Served by PUD No 1 of Franklin County (1 Tracked in Washington)
Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:
3. Frequently Asked Questions (PUD No 1 of Franklin County)
How reliable is PUD No 1 of Franklin County compared to other US utilities?
Under 2025 U.S. EIA Form 861 reporting, PUD No 1 of Franklin County logged 90.6 total outage minutes/year (SAIDI with Major Event Days) and 42 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).
What counties does PUD No 1 of Franklin County serve in Washington?
U.S. EIA Form 861 Service Territory records map PUD No 1 of Franklin County to Franklin County in Washington.
What backup battery or generator size is recommended for PUD No 1 of Franklin County customers?
For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.