LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #12929 • Cooperative • MISO

South Central Indiana REMC (IN) Outage & Grid Reliability

South Central Indiana REMC (U.S. EIA Utility #12929, Cooperative) serves 35,833 total customers across 7 county/counties in Indiana (MISO grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1196.2 outage minutes per year (19.9 hours, SAIDI with major events) across 3.96 interruptions/yr — earning an EP Utility Reliability Grade of B. Observed average residential rate: 17.54¢/kWh.

EIA Outage Time (SAIDI)1196.2 min/yr (19.9 hrs)
Reliability GradeGrade B
Customers Served35,833 Total
Avg Residential Rate17.54¢/kWh
Utility Reliability Summary (South Central Indiana REMC): South Central Indiana REMC (U.S. EIA Utility #12929, Cooperative) serves 35,833 total customers across 7 county/counties in Indiana (MISO grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1196.2 outage minutes per year (19.9 hours, SAIDI with major events) across 3.96 interruptions/yr — earning an EP Utility Reliability Grade of B. Observed average residential rate: 17.54¢/kWh.
Utility Reliability Field Brief • South Central Indiana REMC (IN)

What South Central Indiana REMC Outage Data Means for Customers

South Central Indiana REMC is a cooperative in the MISO balancing authority, serving 35,833 customers across Brown, Clay, Johnson, Monroe, Morgan, and Owen counties. Of those, 35,216 are residential, 606 commercial, and 11 industrial. Residential power averages 17.54 cents per kWh.

The EIA Form 861 numbers say this: SAIDI with major events is 1196.2 minutes a year, about 20 hours. SAIFI is 3.96 interruptions a year. Strip out major events and SAIDI drops to 349.3 minutes, under six hours. So most years are tolerable, but the storm years do the damage. Divide the minutes by the interruptions and you get roughly five hours per outage on average, and rural lines run well above that when a tree takes out a tap far from the substation.

The EP grade is a B, in a high outage duration territory. That is decent, not bulletproof. Plan for almost four interruptions a year and one long event that matters.

Sizing Quiet Home Backup vs. Standby Power in IN

Start with what you cannot live without for a day or two: refrigeration, furnace blower, well pump if you have one, sump pump, internet, some lights, and any medical equipment. Write down the running watts and the starting watts for each. Motors draw several times their running load for a moment at startup, and that surge is what undersizes most generators.

A battery system suits short, frequent outages. With nearly four a year, it carries you through the quick ones silently, with no fuel and no fumes. It struggles when an ice storm drags into a second day, unless you have solar to recharge it or you have kept the loads small.

A standby generator on natural gas or propane, wired through an automatic transfer switch, handles the long events. Rural customers on propane should check their tank level before storm season. Portable generators work if you install an inlet and an interlock or transfer switch. Never backfeed through a dryer outlet, and never run one in a garage. Carbon monoxide kills people every winter.

Many owners do best with a hybrid: a small battery for the critical circuits and a generator for the long haul.

What Local Shops, Clinics & Facilities on South Central Indiana REMC Lines Should Do

Do not guess your exposure. Pull your own outage history, ask the co-op which feeder you sit on, and find out whether it is a long rural line or a short one near a substation. A long radial feeder deserves more backup than the averages suggest.

Shops and small commercial sites should protect the point-of-sale system, refrigeration, network gear, and egress lighting first. Put those on a UPS and then a transfer-switched generator. Test it under load monthly, because a generator that only runs unloaded for ten minutes proves little. Keep fuel fresh and log every test.

Clinics should not assume anything about their backup. Identify which circuits are life-safety, which hold vaccines and records, and which can wait. Confirm with your electrician that the transfer equipment matches those priorities.

Municipal operators should put water plants, lift stations, and dispatch facilities at the top of the list. A lift station with no backup becomes a sewage problem within hours. Pair a generator with a plug-in connection for a portable unit, so a failed machine does not take the site down.

Finally, talk to the co-op before a storm, not during one. Ask about sectionalizing, planned maintenance, and critical-facility flags.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)1196.2 min/yr (19.9 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)3.96 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)302.1 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)349.3 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)35,833 (35,216 / 606 / 11)2025 EIA Form 861
Observed Residential Electricity Rate17.54¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • MISOU.S. EIA Form 861

2. Counties Served by South Central Indiana REMC (7 Tracked in Indiana)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (South Central Indiana REMC)

How reliable is South Central Indiana REMC compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, South Central Indiana REMC logged 1196.2 total outage minutes/year (SAIDI with Major Event Days) and 349.3 minutes/year excluding major storms (High Outage Duration Territory (12–20 hrs/yr)).

What counties does South Central Indiana REMC serve in Indiana?

U.S. EIA Form 861 Service Territory records map South Central Indiana REMC to Brown County, Clay County, Johnson County, Monroe County, Morgan County, Owen County, Putnam County in Indiana.

What backup battery or generator size is recommended for South Central Indiana REMC customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power