LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #21244 • Cooperative • PJM

Southside Electric Coop, Inc (VA) Outage & Grid Reliability

Southside Electric Coop, Inc (U.S. EIA Utility #21244, Cooperative) serves 59,799 total customers across 18 county/counties in Virginia (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 2126.9 outage minutes per year (35.4 hours, SAIDI with major events) across 4.45 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 15.48¢/kWh.

EIA Outage Time (SAIDI)2126.9 min/yr (35.4 hrs)
Reliability GradeGrade CCC
Customers Served59,799 Total
Avg Residential Rate15.48¢/kWh
Utility Reliability Summary (Southside Electric Coop, Inc): Southside Electric Coop, Inc (U.S. EIA Utility #21244, Cooperative) serves 59,799 total customers across 18 county/counties in Virginia (PJM grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 2126.9 outage minutes per year (35.4 hours, SAIDI with major events) across 4.45 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 15.48¢/kWh.
Utility Reliability Field Brief • Southside Electric Coop, Inc (VA)

What Southside Electric Coop, Inc Outage Data Means for Customers

Southside Electric Coop is a cooperative in the PJM balancing authority, serving 59,799 customers: 57,305 residential, 2,474 commercial and 20 industrial. Its territory includes Amelia, Appomattox, Bedford, Brunswick, Buckingham and Campbell counties, among 18 tracked. Residential power averages 15.48 cents per kWh.

The reliability numbers deserve your attention. With major events included, SAIDI is 2126.9 minutes per year, about 35 hours, and SAIFI is 4.45 outages per year. Without major events, SAIDI falls to 323.6 minutes, a little over five hours. That gap is the whole story. On ordinary days the system is tolerable. When a big storm, ice load or a run of fallen timber hits, restoration stretches into days. The EP Utility Grid Reliability Grade here is CCC, severe multi-day outage territory, meaning more than 20 hours a year. Plan for the long outage, not the blink.

Sizing Quiet Home Backup vs. Standby Power in VA

Start with a written load list, not a product catalog. Write down what must run: refrigerator, freezer, well pump, furnace blower, a few lights, router, phone chargers and any medical equipment. Then note which items start on a motor, because well pumps and heat pump compressors pull far more at startup than while running.

A home battery system is quiet, needs no fuel run and handles essentials for hours, sometimes a day or more if you trim loads. It is the right fit for the frequent shorter interruptions that SAIFI of 4.45 implies. It struggles when the outage runs multiple days, unless you have solar to recharge it.

For the multi-day events this CCC grade points to, a permanent standby generator on propane or natural gas with an automatic transfer switch is the proven answer. Size it to your load list with starting surge in mind, not to the biggest unit you can afford. Many homes do best with a modest battery for instant, silent switchover and a generator behind it for the long haul.

Have a licensed electrician do the transfer equipment. Never backfeed a house through a dryer outlet. Run generators outdoors, well away from windows, and keep working carbon monoxide alarms inside. At 15.48 cents per kWh, backup power is about coverage, not savings.

What Local Shops, Clinics & Facilities on Southside Electric Coop, Inc Lines Should Do

Identify your critical loads first: refrigeration, point of sale, phones and data, lighting, egress, heating or cooling, and anything that protects product or people. Put those on a dedicated emergency panel so the generator is not asked to carry everything.

Clinics and care facilities should cover medication and vaccine refrigeration, oxygen equipment and communications. Municipal operators should put water pumps, sewer lift stations, dispatch and administrative buildings first. The 20 industrial accounts should look hard at ride-through for sensitive controls, since a short interruption can cost hours of restart.

Specify automatic transfer, keep a refueling contract and enough fuel on site for several days, and test under real load on a schedule, not just a no-load exercise run. Failed batteries and stale fuel cause more standby failures than the generator itself.

Finally, call the co-op. Ask for the outage history on your specific feeder and whether your site qualifies for priority restoration consideration. Systemwide averages are useful, but your own line is what matters.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)2126.9 min/yr (35.4 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)4.45 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)478.5 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)323.6 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)59,799 (57,305 / 2,474 / 20)2025 EIA Form 861
Observed Residential Electricity Rate15.48¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • PJMU.S. EIA Form 861

2. Counties Served by Southside Electric Coop, Inc (18 Tracked in Virginia)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Southside Electric Coop, Inc)

How reliable is Southside Electric Coop, Inc compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Southside Electric Coop, Inc logged 2126.9 total outage minutes/year (SAIDI with Major Event Days) and 323.6 minutes/year excluding major storms (Severe Multi-Day Outage Territory (>20 hrs/yr)).

What counties does Southside Electric Coop, Inc serve in Virginia?

U.S. EIA Form 861 Service Territory records map Southside Electric Coop, Inc to Amelia County, Appomattox County, Bedford County, Brunswick County, Buckingham County, Campbell County, Charlotte County, Chesterfield County and 10 additional counties in Virginia.

What backup battery or generator size is recommended for Southside Electric Coop, Inc customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power