Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #108 • Cooperative • MISO

Adams-Columbia Electric Coop (WI) Outage & Grid Reliability

Customers served by Adams-Columbia Electric Coop (Cooperative, 39,826 meters across 12 Wisconsin county/counties) lost power an average of 1.8 hours per year (107.9 minutes across 0.87 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 18.98¢/kWh.

EIA Outage Time (SAIDI)107.9 min/yr (1.8 hrs)
Reliability GradeGrade AA
Customers Served39,826 Total
Avg Residential Rate18.98¢/kWh
Utility Reliability Summary (Adams-Columbia Electric Coop): Customers served by Adams-Columbia Electric Coop (Cooperative, 39,826 meters across 12 Wisconsin county/counties) lost power an average of 1.8 hours per year (107.9 minutes across 0.87 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 18.98¢/kWh.
Utility Reliability Field Brief • Adams-Columbia Electric Coop (WI)

What Adams-Columbia Electric Coop Outage Data Means for Customers

Adams-Columbia Electric Coop is a cooperative in the MISO balancing authority, serving 39,826 customers: 36,159 residential, 2,619 commercial, and 1,048 industrial. The 2025 EIA Form 861 shows SAIDI of 107.9 minutes a year with major events and 66.1 minutes without them. SAIFI is 0.87 outages per year. That earns an AA grade, High Grid Reliability, which means 160 minutes a year or less.

In plain terms, the average member loses power a little less than once a year. Divide 107.9 by 0.87 and you get roughly 124 minutes per interruption. The gap between 107.9 and 66.1 is about 42 minutes a year, and that is mostly storm time. Averages hide the tail, though. A member at the end of a long rural tap in Adams, Columbia, Dane, Dodge, Green Lake, or Jefferson County can see worse than the co-op average, and one ice or wind event can run well past the typical figure. This is a good grid, but it is not a perfect one.

Sizing Quiet Home Backup vs. Standby Power in WI

Start with a short list of what must keep running: furnace blower, well pump, sump pump, refrigerator, a few lights, internet, and any medical equipment. Do not size by square footage. Have an electrician add up the real running and starting loads, because motors draw much more when they start than when they run.

With outages that average around two hours, a battery and inverter system is a sensible fit. It is quiet, needs no fuel, and switches over fast. Keep it out of unheated spaces where Wisconsin cold cuts its output, and be honest about how long your essential loads will drain it.

If you live on a long rural line, depend on a well, or heat with electric-dependent equipment through January, a standby generator on natural gas or propane covers the long storm outage that batteries can't. Either way, install a proper transfer switch or interlock. Never backfeed a house through a dryer outlet, because that kills line crews. Run portable generators outdoors, well away from doors and windows, and put a carbon monoxide alarm inside the house.

What Local Shops, Clinics & Facilities on Adams-Columbia Electric Coop Lines Should Do

Figure out what an hour of downtime costs you, then protect only the loads that earn that money back. For a shop, that is usually the point-of-sale system, network gear, coolers, and a few lights. For a clinic, it is medication and vaccine refrigeration, records systems, and exam-room essentials. Put a UPS on anything that can't tolerate even a blink, then add a generator with an automatic transfer switch for longer events.

Remember that SAIDI and SAIFI describe sustained outages. Brief sags and blinks don't show up in them, and they can still reset a controller or crash a server. If you are one of the industrial members, log those events and talk to the co-op about them.

Municipal operators should put generators at water supply, lift stations, and the buildings people go to in an emergency. Keep fuel on hand and rotate it. Exercise every unit monthly under real load, log the results, and service it every year. A generator that has never carried a load is a guess, not a plan. Finally, learn your co-op's outage reporting line and your feeder's name before the storm, not during it.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)107.9 min/yr (1.8 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)0.87 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)123.6 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)66.1 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)39,826 (36,159 / 2,619 / 1,048)2025 EIA Form 861
Observed Residential Electricity Rate18.98¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • MISOU.S. EIA Form 861

2. Counties Served by Adams-Columbia Electric Coop (12 Tracked in Wisconsin)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Adams-Columbia Electric Coop)

How reliable is Adams-Columbia Electric Coop compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Adams-Columbia Electric Coop logged 107.9 total outage minutes/year (SAIDI with Major Event Days) and 66.1 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).

What counties does Adams-Columbia Electric Coop serve in Wisconsin?

U.S. EIA Form 861 Service Territory records map Adams-Columbia Electric Coop to Adams County, Columbia County, Dane County, Dodge County, Green Lake County, Jefferson County, Marquette County, Portage County and 4 additional counties in Wisconsin.

What backup battery or generator size is recommended for Adams-Columbia Electric Coop customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power