U.S. EIA Form 861 Utility Profile • Utility #2409 • Municipal • ERCO

Brownsville Public Utilities Board (TX) Outage & Grid Reliability

Brownsville Public Utilities Board (U.S. EIA Utility #2409, Municipal) serves 55,099 total customers across 1 county/counties in Texas (ERCO grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 152 outage minutes per year (2.5 hours, SAIDI with major events) across 2.99 interruptions/yr — earning an EP Utility Reliability Grade of AA. Observed average residential rate: 11.22¢/kWh.

EIA Outage Time (SAIDI)152 min/yr (2.5 hrs)
Reliability GradeGrade AA
Customers Served55,099 Total
Avg Residential Rate11.22¢/kWh
Utility Reliability Summary (Brownsville Public Utilities Board): Brownsville Public Utilities Board (U.S. EIA Utility #2409, Municipal) serves 55,099 total customers across 1 county/counties in Texas (ERCO grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 152 outage minutes per year (2.5 hours, SAIDI with major events) across 2.99 interruptions/yr — earning an EP Utility Reliability Grade of AA. Observed average residential rate: 11.22¢/kWh.
Utility Reliability Field Brief • Brownsville Public Utilities Board (TX)

What Brownsville Public Utilities Board Outage Data Means for Customers

Brownsville Public Utilities Board is a municipal utility in the ERCO balancing authority, serving 55,099 customers in Cameron County: 48,500 residential, 6,599 commercial, and no industrial. The 2025 EIA Form 861 shows SAIDI of 152.0 minutes a year with major events and 138.6 without them, and SAIFI of 2.99 outages a year. That earns an AA grade, high reliability, under the 160 minute line.

In kitchen-table terms, the average customer sees about three outages a year, roughly 50 minutes each, around two and a half hours total. That is good. But averages hide the tail. A hurricane or a failed feeder can keep your street dark far longer while across town nobody blinks. The gap between 152.0 and 138.6 is what major events add. Plan for short, frequent interruptions first and the rare long one second.

Sizing Quiet Home Backup vs. Standby Power in TX

Start with what you cannot live without: refrigerator, a few lights, router, phone charging, fans, and any medical equipment. Add the running watts, then the startup surge of motors. Size the battery in kilowatt-hours for how long, and the inverter in kilowatts for how much at once. A battery system covers that essentials list quietly, switches over in a fraction of a second, and burns no fuel, which suits the short outages that dominate the record here.

Central air conditioning is where sizing gets expensive. In Valley heat, a compressor pulls hard on startup and drains a modest battery fast. If you need cooling through a multi-day storm, a natural gas or propane standby generator with an automatic transfer switch is the practical answer. Never run a portable generator indoors or in an attached garage, because carbon monoxide kills. Keep it well away from windows and use a proper interlock or transfer switch, never a backfed cord. At 11.22 cents/kWh residential average, backup is insurance, not a savings play.

What Local Shops, Clinics & Facilities on Brownsville Public Utilities Board Lines Should Do

With 6,599 commercial customers on the system, many of you run restaurants, retail, offices and clinics. Expect interruptions and price a 50-minute loss: spoiled cold stock, dead registers, lost sales. Put a UPS on point-of-sale, network gear and servers. That covers the short events that make up most of the record.

Clinics and anyone storing vaccines or medications need a written plan: which circuits are on backup, who tests it, where the fuel is. Exercise the generator under load monthly and log it. Label the backup panel so a night-shift worker can find it in the dark. Municipal operators should treat water and wastewater pumping, traffic signals and communications as priority loads, on separate panels, tested before hurricane season, with a fuel contact on file. Ask Brownsville Public Utilities Board for your feeder's outage history and size from that, not the citywide average.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)152 min/yr (2.5 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)2.99 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)50.8 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)138.6 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)55,099 (48,500 / 6,599 / 0)2025 EIA Form 861
Observed Residential Electricity Rate11.22¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityMunicipal • ERCOU.S. EIA Form 861

2. Counties Served by Brownsville Public Utilities Board (1 Tracked in Texas)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Brownsville Public Utilities Board)

How reliable is Brownsville Public Utilities Board compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Brownsville Public Utilities Board logged 152 total outage minutes/year (SAIDI with Major Event Days) and 138.6 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).

What counties does Brownsville Public Utilities Board serve in Texas?

U.S. EIA Form 861 Service Territory records map Brownsville Public Utilities Board to Cameron County in Texas.

What backup battery or generator size is recommended for Brownsville Public Utilities Board customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power