Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #3107 • Cooperative • CPLE

Carteret-Craven El Member Corp (NC) Outage & Grid Reliability

Customers served by Carteret-Craven El Member Corp (Cooperative, 43,756 meters across 4 North Carolina county/counties) lost power an average of 2.0 hours per year (117.7 minutes across 1.55 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 12.46¢/kWh.

EIA Outage Time (SAIDI)117.7 min/yr (2.0 hrs)
Reliability GradeGrade AA
Customers Served43,756 Total
Avg Residential Rate12.46¢/kWh
Utility Reliability Summary (Carteret-Craven El Member Corp): Customers served by Carteret-Craven El Member Corp (Cooperative, 43,756 meters across 4 North Carolina county/counties) lost power an average of 2.0 hours per year (117.7 minutes across 1.55 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 12.46¢/kWh.
Utility Reliability Field Brief • Carteret-Craven El Member Corp (NC)

What Carteret-Craven El Member Corp Outage Data Means for Customers

Carteret-Craven Electric is a cooperative on the CPLE balancing authority. It serves 43,756 customers across Carteret, Craven, Jones, and Onslow counties: 39,424 residential, 4,331 commercial, and one industrial. Residential customers pay an observed average of 12.46 cents per kWh.

The 2025 EIA Form 861 data shows SAIDI of 117.7 minutes a year with major events counted and 72.3 minutes without them. SAIFI is 1.55 outages per year. EP grades that AA, high reliability, meaning 160 minutes a year or less. In plain terms, the average member loses power a bit more than once and a half a year, and a typical interruption runs about an hour. The roughly 45 minutes between those two SAIDI figures comes from major events, which on this coast usually means storms. Averages hide the tail, though. A member at the end of a long rural tap can see worse than the system number, and a hurricane can cause an outage that never shows up in a normal year.

Sizing Quiet Home Backup vs. Standby Power in NC

Start by listing what you can't lose: refrigeration, a well pump if you have one, medical equipment, a few lights, internet, and a fan or heat source. Add those loads up before you shop. A battery with an inverter handles short, frequent interruptions silently and switches over without a flicker. With typical outages around an hour, it covers most years well. Its limit is stored energy. Once it's drained, you're waiting on sun or the grid.

For multi-day storm outages, a permanent standby generator on natural gas or propane is the proven answer. Size it to the loads you actually run, including the starting surge on air conditioners and well pumps. Have a licensed electrician install a transfer switch. Never backfeed through a dryer outlet. Keep the unit outdoors, well away from windows, and run a carbon monoxide alarm inside. Look for U.S. EPA-certified equipment, exercise it on schedule, and plan your fuel supply honestly.

Many coastal homes do best with both: a battery for the nuisance outages and a generator for the long ones. In flood-prone areas, mount equipment above expected water levels.

What Local Shops, Clinics & Facilities on Carteret-Craven El Member Corp Lines Should Do

Figure out what an hour of downtime costs you before you buy anything. Most commercial members see the same 1.55 outages a year as everyone else, and the ones that hurt are the rare long ones. Put a UPS on point-of-sale, servers, and network gear so a blink doesn't corrupt data or crash a register. Put a standby generator with an automatic transfer switch on life-safety lighting, refrigeration, and the circuits that keep you open.

Clinics should write down which loads can't drop: vaccine and medication refrigeration, powered medical devices, and records access. Then confirm the backup actually carries them.

Municipal operators should treat water pumping, wastewater lift stations, communications, and shelters as priority loads. Keep a written priority list and a fuel log. Test under real load monthly, not just with a no-load run. Service transfer switches every year, and talk to the co-op about which feeders your critical sites sit on.

Backup power fails mostly from neglect, not bad design. Test it before the storm, not during.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)117.7 min/yr (2.0 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.55 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)76.1 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)72.3 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)43,756 (39,424 / 4,331 / 1)2025 EIA Form 861
Observed Residential Electricity Rate12.46¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • CPLEU.S. EIA Form 861

2. Counties Served by Carteret-Craven El Member Corp (4 Tracked in North Carolina)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Carteret-Craven El Member Corp)

How reliable is Carteret-Craven El Member Corp compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Carteret-Craven El Member Corp logged 117.7 total outage minutes/year (SAIDI with Major Event Days) and 72.3 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).

What counties does Carteret-Craven El Member Corp serve in North Carolina?

U.S. EIA Form 861 Service Territory records map Carteret-Craven El Member Corp to Carteret County, Craven County, Jones County, Onslow County in North Carolina.

What backup battery or generator size is recommended for Carteret-Craven El Member Corp customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power