LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #8901 • Investor Owned

CenterPoint Energy (TX) Outage & Grid Reliability

CenterPoint Energy (U.S. EIA Utility #8901, Investor Owned) serves 2,898,292 total customers across 12 county/counties in Texas. In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 193.2 outage minutes per year (3.2 hours, SAIDI with major events) across 1.95 interruptions/yr — earning an EP Utility Reliability Grade of A.

EIA Outage Time (SAIDI)193.2 min/yr (3.2 hrs)
Reliability GradeGrade A
Customers Served2,898,292 Total
Avg Residential RateSee Tariff
Utility Reliability Summary (CenterPoint Energy): CenterPoint Energy (U.S. EIA Utility #8901, Investor Owned) serves 2,898,292 total customers across 12 county/counties in Texas. In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 193.2 outage minutes per year (3.2 hours, SAIDI with major events) across 1.95 interruptions/yr — earning an EP Utility Reliability Grade of A.
Utility Reliability Field Brief • CenterPoint Energy (TX)

What CenterPoint Energy Outage Data Means for Customers

CenterPoint Energy is an investor-owned utility, and EIA lists 2,898,292 customers served. The residential, commercial, and industrial splits show as zero in this filing, so read that as "not broken out," not "none." The residential rate is also not separately reported, so I won't quote a price per kilowatt-hour.

The 2025 EIA Form 861 reliability numbers are SAIDI of 193.2 minutes per year with major events and 151.1 minutes without them. SAIFI is 1.95 outages per year. That earns an A grade, which means above-average reliability at or under 260 minutes a year. Divide 193.2 by 1.95 and a typical interruption runs roughly 99 minutes. The gap between the two SAIDI figures is 42.1 minutes, and that is the share caused by major events like storms.

Those numbers are averages across a huge system. Your feeder, your tree cover, and your distance from the substation decide your real experience. The counties in the tracked list include Austin, Brazoria, Chambers, Colorado, Fort Bend, and Galveston. They cover a lot of different terrain, from coastal exposure to inland overhead lines. An A grade tells you the typical year is decent. It does not tell you that a bad storm week won't take you out for days.

Sizing Quiet Home Backup vs. Standby Power in TX

Start with a list, not a product. Write down what must keep running: refrigerator, a few lights, internet, phone charging, any medical equipment, and a fan or heating source. Then separate running load from startup surge. Motors like well pumps and air conditioners kick hard on startup, and that surge is what undersizes most systems.

With roughly one outage a year and an average of about 99 minutes, a battery system handles the common event quietly. It carries essentials through a typical interruption with no fuel and no noise. The 42.1 minutes of major-event time is the reason to think longer. In a multi-day storm, a battery alone runs dry unless you can recharge it from solar or a generator.

A permanent standby generator on natural gas or propane suits whole-house coverage, but it needs proper transfer equipment, permits, and clearances from windows and doors. Never run a portable unit in a garage or near an intake, because carbon monoxide kills quietly. Check the U.S. EPA emissions labeling and your local noise and permit rules before buying. Many people do best with a modest battery for the short outages and a generator inlet for the rare long one.

What Local Shops, Clinics & Facilities on CenterPoint Energy Lines Should Do

Decide what a lost hour actually costs you, then work backward. A shop with refrigeration or point-of-sale systems needs a small battery or UPS for the typical interruption, plus a plan for extended loss. Know your critical circuits and put them on a separate panel so you aren't trying to back up the whole building.

Clinics and care facilities should treat backup as a tested system, not a purchase. Run your generator under real load on a schedule, keep fuel supply realistic, and log the results. Confirm your transfer switch works before the storm, not during it. Check with your own regulators about what your type of facility must maintain, because I won't guess at that for you.

Municipal operators should rank facilities by consequence: water and wastewater pumping, communications, and shelters first. Coastal and flood-prone locations like those in Galveston, Brazoria, and Chambers counties need generators and fuel stored above flood level. Ask CenterPoint Energy about your feeder's history and any priority-restoration status. Averages are a starting point. Your own outage log is the better guide.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)193.2 min/yr (3.2 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.95 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)98.9 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)151.1 min/yrWithout Major Event Days
Total Customers2,898,292 (Delivery / Total Metered)2025 EIA Form 861
Observed Residential Electricity RateNot Separately Reported2025 EIA Revenues / MWh
Ownership & Balancing AuthorityInvestor OwnedU.S. EIA Form 861

2. Counties Served by CenterPoint Energy (12 Tracked in Texas)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (CenterPoint Energy)

How reliable is CenterPoint Energy compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, CenterPoint Energy logged 193.2 total outage minutes/year (SAIDI with Major Event Days) and 151.1 minutes/year excluding major storms (Above-Average Reliability (<=260 min/yr)).

What counties does CenterPoint Energy serve in Texas?

U.S. EIA Form 861 Service Territory records map CenterPoint Energy to Austin County, Brazoria County, Chambers County, Colorado County, Fort Bend County, Galveston County, Harris County, Liberty County and 4 additional counties in Texas.

What backup battery or generator size is recommended for CenterPoint Energy customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power