Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #554 • Municipal • MISO

City of Ames - (IA) (IA) Outage & Grid Reliability

Customers served by City of Ames - (IA) (Municipal, 28,239 meters across 1 Iowa county/counties) lost power an average of 0.4 hours per year (21.1 minutes across 0.39 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 12.12¢/kWh.

EIA Outage Time (SAIDI)21.1 min/yr (0.4 hrs)
Reliability GradeGrade AAA
Customers Served28,239 Total
Avg Residential Rate12.12¢/kWh
Utility Reliability Summary (City of Ames - (IA)): Customers served by City of Ames - (IA) (Municipal, 28,239 meters across 1 Iowa county/counties) lost power an average of 0.4 hours per year (21.1 minutes across 0.39 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 12.12¢/kWh.
Utility Reliability Field Brief • City of Ames - (IA) (IA)

What City of Ames - (IA) Outage Data Means for Customers

Ames is a municipal utility in the MISO balancing authority, serving 28,239 customers: 25,123 residential, 3,109 commercial, and 7 industrial. The 2025 EIA Form 861 numbers are strong. SAIDI is 21.1 minutes per year and SAIFI is 0.39 outages per year. The figure is the same with and without major events, so storms are not skewing the picture. Put those together and the average interruption lasts a bit under an hour, and you would see one roughly every two and a half years. That earns an EP grade of AAA, top-decile reliability. Residential customers pay an average of 12.12 cents/kWh.

Here is the catch. Those are system averages spread across every meter. If you sit at the end of a long overhead line or under mature trees, your experience can run worse than the number on paper. A good average also says nothing about the one bad day, like a derecho or ice storm that takes out a neighborhood. Keep your own outage log. Your history beats the average.

Sizing Quiet Home Backup vs. Standby Power in IA

With outages this rare and short, most Ames homes do not need a whole-house standby generator. Start by listing what you cannot lose: sump pump, furnace blower, refrigerator, internet router, phone chargers, and a few lights. In an Iowa January, the furnace blower matters most, because a gas furnace without its fan is just a cold house.

A battery station or home battery sized to that short list rides through a typical under-an-hour event quietly, with no fuel and no exhaust. Add an engine-driven generator only if you have medical equipment, a long-duration storm plan, or loads a battery cannot carry. Size it from your actual load list, not from a brochure.

If you go portable, run it outdoors, well away from windows and doors, never in the garage. Install a carbon monoxide alarm. Have a licensed electrician install a proper inlet and interlock or transfer switch. Never backfeed a house through a dryer outlet, because that endangers line crews. For permanent standby units, pull the city permit and confirm the unit carries U.S. EPA emissions certification.

What Local Shops, Clinics & Facilities on City of Ames - (IA) Lines Should Do

Start by working out what an hour of downtime costs you. For most shops, that means coolers, point-of-sale, network gear, and phones. A small UPS on the router, server, and registers covers short interruptions and gives you time to shut down cleanly. For many retail and office sites, that is the whole plan.

Clinics and care facilities should separate life-safety and medical loads from convenience loads. Put them on a transfer switch, keep vaccine and medication refrigeration on backed-up circuits, and test under real load monthly, not just a no-load run. Keep fuel fresh and know who services the unit after hours.

Municipal operators should rank critical loads: water and wastewater lift stations, traffic signals, dispatch and communications, and shelters. Document each transfer switch, exercise generators on a schedule, and load-bank test them yearly. The 7 industrial customers should check how their process controls react to voltage sags, which often cause more trouble than outages. Talk with the city electric department about your feeder and its restoration priority before the storm.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)21.1 min/yr (0.4 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)0.39 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)54 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)21.1 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)28,239 (25,123 / 3,109 / 7)2025 EIA Form 861
Observed Residential Electricity Rate12.12¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityMunicipal • MISOU.S. EIA Form 861

2. Counties Served by City of Ames - (IA) (1 Tracked in Iowa)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (City of Ames - (IA))

How reliable is City of Ames - (IA) compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, City of Ames - (IA) logged 21.1 total outage minutes/year (SAIDI with Major Event Days) and 21.1 minutes/year excluding major storms (Top-Decile Grid Reliability (<=90 min/yr)).

What counties does City of Ames - (IA) serve in Iowa?

U.S. EIA Form 861 Service Territory records map City of Ames - (IA) to Story County in Iowa.

What backup battery or generator size is recommended for City of Ames - (IA) customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power