Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #14268 • Municipal • LGEE

City of Owensboro - (KY) (KY) Outage & Grid Reliability

Customers served by City of Owensboro - (KY) (Municipal, 26,589 meters across 1 Kentucky county/counties) lost power an average of 1.5 hours per year (87.4 minutes across 1.14 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 13.4¢/kWh.

EIA Outage Time (SAIDI)87.4 min/yr (1.5 hrs)
Reliability GradeGrade AAA
Customers Served26,589 Total
Avg Residential Rate13.4¢/kWh
Utility Reliability Summary (City of Owensboro - (KY)): Customers served by City of Owensboro - (KY) (Municipal, 26,589 meters across 1 Kentucky county/counties) lost power an average of 1.5 hours per year (87.4 minutes across 1.14 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 13.4¢/kWh.
Utility Reliability Field Brief • City of Owensboro - (KY) (KY)

What City of Owensboro - (KY) Outage Data Means for Customers

Owensboro's municipal system reports a SAIDI of 87.4 minutes per year and a SAIFI of 1.14 outages per year in the 2025 EIA Form 861 data. In practice, the average customer loses power a little more than once a year, for about an hour and a half total. Divide one by the other and a typical interruption runs somewhere around 77 minutes. The with-major-events and without-major-events figures are identical at 87.4, so the number isn't being flattered by excluding storm days. That earns the AAA grade, which is the top-decile tier at 90 minutes a year or less.

Averages hide the tail, though. Most of the 26,589 customers (23,316 residential, 3,186 commercial, 87 industrial) will see something close to this. A few on long radial feeders or tree-heavy streets in Daviess County will see worse, and an ice storm can still blow through any average. Residential power averages 13.4 cents per kWh, so running a generator on fuel will almost always cost more per kWh than the grid. Treat backup as insurance, not savings.

Sizing Quiet Home Backup vs. Standby Power in KY

With outages this short, most homes don't need a whole-house system. Start by listing what actually hurts when it goes dark: refrigerator, sump pump, furnace blower, internet, a few lights, and any medical equipment. Add up the running watts, then check the starting surge on motors like the well pump, the sump pump, and the compressor. Surge is what trips undersized units.

A battery system with an inverter is quiet, needs no fuel, and handles a 77-minute outage without any noise or fumes. It struggles with multi-day events and heavy loads like electric heat. A permanently installed natural gas or propane standby generator covers long outages, but it needs a transfer switch, a permit, proper clearances, and a maintenance routine. If you buy a portable unit, look for U.S. EPA-compliant engines. Never run one in a garage, and never backfeed through a dryer outlet. That kills line crews.

For most Owensboro households, a small battery for essentials plus a properly interlocked portable generator for the rare long event is the sensible middle path.

What Local Shops, Clinics & Facilities on City of Owensboro - (KY) Lines Should Do

For the 3,186 commercial and 87 industrial accounts, an hour-plus outage costs money in ways a homeowner never sees. Lost point-of-sale, spoiled inventory, dropped network sessions, and restarting equipment all add up. Start with a short list of loads that must stay up, such as refrigeration, servers, phones, egress lighting, and any life-safety systems. Put those on a dedicated critical-loads panel.

Use an uninterruptible power supply for anything that corrupts when it drops: computers, controls, and network gear. Size it to ride through a few minutes and let a generator take over from there. Where outages cost serious money, a standby generator with an automatic transfer switch is worth pricing. Test it under load monthly and exercise it on schedule. Most generator failures come from stale fuel, dead batteries, and untested transfer switches, not from the engine itself.

Clinics and care facilities should confirm with their own regulators and engineers what backup is required for their services. Industrial customers should ask the utility about feeder configuration and whether sensitive motors need ride-through protection, since a momentary blink can do more damage than a clean outage.

Everyone should keep the utility's outage line saved, know where your main breaker is, and document your setup. Good data helps, but your own plan is what keeps you running.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)87.4 min/yr (1.5 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.14 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)77 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)87.4 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)26,589 (23,316 / 3,186 / 87)2025 EIA Form 861
Observed Residential Electricity Rate13.4¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityMunicipal • LGEEU.S. EIA Form 861

2. Counties Served by City of Owensboro - (KY) (1 Tracked in Kentucky)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (City of Owensboro - (KY))

How reliable is City of Owensboro - (KY) compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, City of Owensboro - (KY) logged 87.4 total outage minutes/year (SAIDI with Major Event Days) and 87.4 minutes/year excluding major storms (Top-Decile Grid Reliability (<=90 min/yr)).

What counties does City of Owensboro - (KY) serve in Kentucky?

U.S. EIA Form 861 Service Territory records map City of Owensboro - (KY) to Daviess County in Kentucky.

What backup battery or generator size is recommended for City of Owensboro - (KY) customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power