Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #10000 • Investor Owned • SWPP

Evergy Metro (KS) Outage & Grid Reliability

Customers served by Evergy Metro (Investor Owned, 279,835 meters across 11 Kansas county/counties) lost power an average of 2.1 hours per year (128.5 minutes across 1.02 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 13.21¢/kWh.

EIA Outage Time (SAIDI)128.5 min/yr (2.1 hrs)
Reliability GradeGrade AA
Customers Served279,835 Total
Avg Residential Rate13.21¢/kWh
Utility Reliability Summary (Evergy Metro): Customers served by Evergy Metro (Investor Owned, 279,835 meters across 11 Kansas county/counties) lost power an average of 2.1 hours per year (128.5 minutes across 1.02 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 13.21¢/kWh.
Utility Reliability Field Brief • Evergy Metro (KS)

What Evergy Metro Outage Data Means for Customers

Evergy Metro is an investor-owned utility in the SWPP balancing authority. It serves 279,835 customers: 247,426 residential, 31,600 commercial, and 809 industrial. Tracked counties include Anderson, Bourbon, Coffey, Douglas, Franklin, and Johnson. Residential power averages 13.21 cents/kWh.

The 2025 EIA Form 861 numbers are a SAIDI of 128.5 minutes per year with major events and a SAIFI of 1.02 outages per year. Without major events, SAIDI falls to 64.3 minutes. So about half the average outage time comes from big storm days, not everyday faults. Divide 128.5 by 1.02 and a typical interruption runs roughly two hours. That earns the AA grade, high reliability at 160 minutes per year or less.

Averages hide the tail, though. A customer at the end of a long, tree-lined feeder can see far worse than the utility-wide figure, and a bad ice or wind event can outlast any average. Treat these numbers as your baseline, not your guarantee.

Sizing Quiet Home Backup vs. Standby Power in KS

Start by listing what must keep running: refrigerator, furnace blower, sump pump, well pump, medical devices, internet, and some lights. Everything else can wait.

With roughly one outage a year averaging a couple of hours, a battery system fits most homes. It is silent, burns no fuel, and switches over fast. Size it to the loads you listed, not the whole house. Its weakness is the multi-day storm. Once the battery drains with no sun or grid to recharge it, you are dark.

If you can't tolerate long storm outages, a standby generator on natural gas or propane with an automatic transfer switch is the answer. Have an electrician do a real load calculation. Motors such as central air and well pumps draw far more current starting than running, and that surge is what undersizes most units. Pull permits, use a proper transfer switch or interlock, and never backfeed through a dryer outlet.

Keep generators well away from windows and doors, and install carbon monoxide alarms. Run any generator under real load on a regular schedule. Many fail on the first day of a storm because nobody ever tested them.

What Local Shops, Clinics & Facilities on Evergy Metro Lines Should Do

Sort your loads into three tiers: life-safety, mission-critical, and convenience. Back up the first two and let the third go dark.

Shops and restaurants should protect refrigeration, point-of-sale, network gear, and egress lighting. Clinics should protect vaccine and medication refrigeration, essential medical equipment, records systems, and phones. A UPS covers the gap while a generator starts, and an automatic transfer switch carries the load after that. Make sure fuel supply matches how long you need to run.

Municipal operators should look hardest at lift stations, water pumping, traffic signals, and dispatch centers. Know which sites have fixed generators, which rely on portable units, and who moves them. Keep a written fuel plan and a tested connection point at each site.

Industrial and larger commercial customers should remember that SAIDI counts sustained outages. Voltage sags and momentary blips do not show up in it, yet they can trip processes and drives. Ride-through protection is cheap compared with a restart.

Stationary engines are subject to U.S. EPA emissions rules and state permitting, so confirm requirements before you buy. Then write a one-page outage procedure, assign names, and drill it once a year.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)128.5 min/yr (2.1 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.02 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)126.1 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)64.3 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)279,835 (247,426 / 31,600 / 809)2025 EIA Form 861
Observed Residential Electricity Rate13.21¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityInvestor Owned • SWPPU.S. EIA Form 861

2. Counties Served by Evergy Metro (11 Tracked in Kansas)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Evergy Metro)

How reliable is Evergy Metro compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Evergy Metro logged 128.5 total outage minutes/year (SAIDI with Major Event Days) and 64.3 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).

What counties does Evergy Metro serve in Kansas?

U.S. EIA Form 861 Service Territory records map Evergy Metro to Anderson County, Bourbon County, Coffey County, Douglas County, Franklin County, Johnson County, Leavenworth County, Linn County and 3 additional counties in Kansas.

What backup battery or generator size is recommended for Evergy Metro customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power