Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #6491 • Municipal • SOCO

Foley Board of Utilities (AL) Outage & Grid Reliability

Customers served by Foley Board of Utilities (Municipal, 61,343 meters across 1 Alabama county/counties) lost power an average of 1.2 hours per year (70.3 minutes across 1.07 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 13.97¢/kWh.

EIA Outage Time (SAIDI)70.3 min/yr (1.2 hrs)
Reliability GradeGrade AAA
Customers Served61,343 Total
Avg Residential Rate13.97¢/kWh
Utility Reliability Summary (Foley Board of Utilities): Customers served by Foley Board of Utilities (Municipal, 61,343 meters across 1 Alabama county/counties) lost power an average of 1.2 hours per year (70.3 minutes across 1.07 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 13.97¢/kWh.
Utility Reliability Field Brief • Foley Board of Utilities (AL)

What Foley Board of Utilities Outage Data Means for Customers

Foley Board of Utilities is a municipal system buying power through the SOCO balancing authority. It serves 61,343 customers in Baldwin County: 53,818 residential, 7,522 commercial, and 3 industrial. EIA Form 861 shows SAIDI of 70.3 minutes a year with major events counted and 40.5 minutes without them. SAIFI is 1.07, so the average customer sees about one interruption a year. That earns an AAA grade, top-decile reliability at under 90 minutes a year.

In a normal year, expect to lose power about once, for roughly an hour. The gap between 70.3 and 40.5 minutes is storm weather. Averages hide the tail, though. A hurricane or tornado can leave one feeder down for days while the system numbers still look good. With residential power at 13.97 cents per kWh, backup is not a money-saving play. It is insurance against that tail.

Sizing Quiet Home Backup vs. Standby Power in AL

Start with a load list, not a product catalog. Write down the refrigerator, freezer, lights, internet, phone chargers, any medical device, the furnace blower, and a well pump if you have one. Note running watts and the higher starting surge on motors. Central air and electric strip heat are what push a whole-house system into serious money, so decide up front whether you are backing those up.

For the typical hour-long interruption, a battery inverter system carrying essential circuits is quiet, fast, and has no fuel to store. For multi-day storm outages, a standby generator on natural gas or propane with an automatic transfer switch is the better fit. Gas service can be disrupted too, so keep a fuel plan.

Hire a licensed electrician and pull the permit. Never backfeed a house through a dryer outlet. Run portable generators outdoors, well away from windows and doors, and keep working carbon monoxide detectors inside.

What Local Shops, Clinics & Facilities on Foley Board of Utilities Lines Should Do

Rank your loads by what costs you most when it drops: refrigeration, point-of-sale, servers, phones, egress lighting, and any medical equipment. Put a UPS on anything that cannot reboot gracefully. That covers the typical short interruption. Add a generator and transfer switch for anything that must run through a storm.

Clinics should treat vaccine and medication refrigeration and oxygen equipment as first-priority circuits, and should write down who does what at hour one, hour six, and hour twenty-four.

Municipal operators should look hardest at lift stations, water pumps, traffic signals, and radio sites. Know your generator runtime on a full tank, have a refueling contract, and keep portable connection points ready for the sites that matter most.

Everyone should exercise generators monthly under real load, service them yearly, and test the transfer switch. Anything that could run in parallel with the grid needs a conversation with Foley Board of Utilities before installation, not after.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)70.3 min/yr (1.2 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.07 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)65.8 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)40.5 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)61,343 (53,818 / 7,522 / 3)2025 EIA Form 861
Observed Residential Electricity Rate13.97¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityMunicipal • SOCOU.S. EIA Form 861

2. Counties Served by Foley Board of Utilities (1 Tracked in Alabama)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Foley Board of Utilities)

How reliable is Foley Board of Utilities compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Foley Board of Utilities logged 70.3 total outage minutes/year (SAIDI with Major Event Days) and 40.5 minutes/year excluding major storms (Top-Decile Grid Reliability (<=90 min/yr)).

What counties does Foley Board of Utilities serve in Alabama?

U.S. EIA Form 861 Service Territory records map Foley Board of Utilities to Baldwin County in Alabama.

What backup battery or generator size is recommended for Foley Board of Utilities customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power