Kingsport Power Co (TN) Outage & Grid Reliability
Customers served by Kingsport Power Co (Investor Owned, 49,694 meters across 3 Tennessee county/counties) lost power an average of 3.0 hours per year (181.9 minutes across 1.13 outages/yr in 2025 federal EIA filings) — earning Reliability Grade A. Average residential electricity rate: 12.28¢/kWh.
What Kingsport Power Co Outage Data Means for Customers
Kingsport Power Co is an investor-owned utility serving 49,694 customers in Hawkins, Sullivan, and Washington Counties, inside the PJM balancing authority. That breaks down to 43,364 residential, 6,137 commercial, and 193 industrial accounts. EIA Form 861 shows SAIDI of 181.9 minutes per year with major events and 158.0 without them, plus SAIFI of 1.13 interruptions per year. Divide it out and the average customer sees about one outage a year, lasting somewhere near three hours. That earns an A grade, inside the 260-minute line for above-average reliability.
Averages hide the tail, though. The gap between 181.9 and 158.0 is major-event time, the storm days. A customer at the end of a long rural feeder can sit well outside the average. Plan for your worst day, not the mean.
Sizing Quiet Home Backup vs. Standby Power in TN
With numbers like these, most homes do not need a whole-house generator to get through a typical year. A battery system sized for essentials covers the common outage: refrigerator, freezer, router, lights, phone charging, a medical device, and maybe a furnace blower. Start by listing what must run. Read the running watts and starting surge off the nameplates, then size to that list. Heat pumps, electric ranges, and well pumps are what blow up budgets.
A standby generator makes sense if you have a well pump, medical equipment that cannot stop, or a home far out on a long line where storm restoration drags. At 12.28 cents per kWh residential, grid power is cheap enough that backup is about resilience, not savings. Weigh fuel storage, noise, and U.S. EPA emissions rules for engines. Never run a portable unit in a garage or near a window. Have an electrician install a transfer switch or interlock. Back-feeding a house through a dryer outlet is how linemen get hurt.
What Local Shops, Clinics & Facilities on Kingsport Power Co Lines Should Do
If you are one of the 6,137 commercial or 193 industrial accounts, treat a roughly three-hour interruption as a planning case. Walk your panel and sort loads into three groups: must stay on, should stay on, and can wait. Put a UPS on servers, point-of-sale, phones, and anything that corrupts data or loses calibration on a dip. Refrigeration for food, vaccines, or samples needs its own plan, because a freezer does not care that the average outage was short.
For longer runs, use a standby generator with an automatic transfer switch, and test it monthly under real load. Most failed generators had a dead battery, stale fuel, or a tripped breaker nobody checked. Keep a written fuel plan and a tested restart procedure.
Municipal operators should put water pumping, wastewater lift stations, signals, and dispatch communications at the top of the list. Keep a simple outage log by feeder, with dates, durations, and what failed. Take that log to your utility account representative. A documented pattern gets attention faster than a phone call after the fact.
1. Official U.S. EIA Form 861 Reliability & Customer Record
| EIA Form 861 Metric | Observed Utility Value | Reporting Basis |
|---|---|---|
| SAIDI (Total Outage Minutes / Year) | 181.9 min/yr (3.0 hrs) | All Events w/ Major Event Days (2025) |
| SAIFI (Average Outages / Year) | 1.13 interruptions/yr | IEEE / Utility Standard w/ MED |
| CAIDI (Avg Restoration Minutes / Outage) | 160.7 min/outage | Average Customer Outage Duration |
| SAIDI (Blue-Sky / Excluding Major Storms) | 158 min/yr | Without Major Event Days |
| Total Customers (Res / Com / Ind) | 49,694 (43,364 / 6,137 / 193) | 2025 EIA Form 861 |
| Observed Residential Electricity Rate | 12.28¢/kWh | 2025 EIA Revenues / MWh |
| Ownership & Balancing Authority | Investor Owned • PJM | U.S. EIA Form 861 |
2. Counties Served by Kingsport Power Co (3 Tracked in Tennessee)
Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:
3. Frequently Asked Questions (Kingsport Power Co)
How reliable is Kingsport Power Co compared to other US utilities?
Under 2025 U.S. EIA Form 861 reporting, Kingsport Power Co logged 181.9 total outage minutes/year (SAIDI with Major Event Days) and 158 minutes/year excluding major storms (Above-Average Reliability (<=260 min/yr)).
What counties does Kingsport Power Co serve in Tennessee?
U.S. EIA Form 861 Service Territory records map Kingsport Power Co to Hawkins County, Sullivan County, Washington County in Tennessee.
What backup battery or generator size is recommended for Kingsport Power Co customers?
For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.
- Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
- Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
- Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
Our risk-free engineering & satisfaction guarantee
Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.