Laclede Electric Coop, Inc (MO) Outage & Grid Reliability
Customers served by Laclede Electric Coop, Inc (Cooperative, 39,257 meters across 6 Missouri county/counties) lost power an average of 2.6 hours per year (155.4 minutes across 2.07 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 12.39¢/kWh.
What Laclede Electric Coop, Inc Outage Data Means for Customers
Laclede Electric Coop, Inc is a cooperative serving 39,257 customers in Camden, Dallas, Laclede, Pulaski, Webster, and Wright counties, with power supplied through the AECI balancing authority. That count is 35,275 residential, 3,968 commercial, and 14 industrial. Residential customers pay an average of 12.39 cents/kWh.
The 2025 EIA Form 861 shows SAIDI of 155.4 minutes a year with major events and 123.1 without them. SAIFI is 2.07 outages a year. In plain terms, the average member loses power a little over twice a year, for about 2.6 hours total. Divide it out and a typical outage runs roughly an hour. The gap of about 32 minutes between the two SAIDI figures is what major storms add. EP grades this AA, high reliability, under the 160 minute line. Averages hide the tail, though. If you live at the end of a long rural tap, expect worse than the system number, and a bad storm year can blow past it.
Sizing Quiet Home Backup vs. Standby Power in MO
With outages that are short and fairly infrequent, a battery and inverter system covers most households. It is silent, indoors-safe, and has no fuel to stale. Size it for essentials: refrigerator, lights, internet, furnace blower, sump pump, and a well pump if you have one. Add up running watts, then check starting surge. Motors are where people get burned, and well pumps and air conditioner compressors are the usual culprits.
If you rely on a well, medical equipment, or you sit on a long radial line, a standby generator on propane or natural gas is the better tool for multi-day storm events. It carries heavier loads for longer than a battery can.
Either way, have a licensed electrician install a transfer switch or interlock. Never backfeed a house through a dryer outlet, because it can kill a lineman. Keep portable generators outdoors, well away from windows and doors, and put a working carbon monoxide alarm inside. Exercise any generator monthly and under load.
What Local Shops, Clinics & Facilities on Laclede Electric Coop, Inc Lines Should Do
Start with a written critical-load list: refrigeration, point-of-sale, phones, network gear, lighting for safe egress, and anything that protects inventory or people. Everything else gets shed during an outage. Most businesses oversize a generator for loads they could simply turn off.
Put a UPS on servers and registers to bridge the gap before the generator picks up. Use an automatic transfer switch where downtime costs real money. Test under actual load, not just idling, and log fuel runtime honestly.
Clinics should treat vaccine and medication refrigeration, oxygen concentrators, and records systems as the first loads on backup. Municipal operators should do the same for lift stations, water wells and pumps, and dispatch and city hall communications, and each site needs a fuel plan and a portable-generator connection point.
Call the cooperative and ask about outage history on your specific feeder. Systemwide numbers are good context, but your tap is what decides how much backup you need.
1. Official U.S. EIA Form 861 Reliability & Customer Record
| EIA Form 861 Metric | Observed Utility Value | Reporting Basis |
|---|---|---|
| SAIDI (Total Outage Minutes / Year) | 155.4 min/yr (2.6 hrs) | All Events w/ Major Event Days (2025) |
| SAIFI (Average Outages / Year) | 2.07 interruptions/yr | IEEE / Utility Standard w/ MED |
| CAIDI (Avg Restoration Minutes / Outage) | 75.1 min/outage | Average Customer Outage Duration |
| SAIDI (Blue-Sky / Excluding Major Storms) | 123.1 min/yr | Without Major Event Days |
| Total Customers (Res / Com / Ind) | 39,257 (35,275 / 3,968 / 14) | 2025 EIA Form 861 |
| Observed Residential Electricity Rate | 12.39¢/kWh | 2025 EIA Revenues / MWh |
| Ownership & Balancing Authority | Cooperative • AECI | U.S. EIA Form 861 |
2. Counties Served by Laclede Electric Coop, Inc (6 Tracked in Missouri)
Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:
3. Frequently Asked Questions (Laclede Electric Coop, Inc)
How reliable is Laclede Electric Coop, Inc compared to other US utilities?
Under 2025 U.S. EIA Form 861 reporting, Laclede Electric Coop, Inc logged 155.4 total outage minutes/year (SAIDI with Major Event Days) and 123.1 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).
What counties does Laclede Electric Coop, Inc serve in Missouri?
U.S. EIA Form 861 Service Territory records map Laclede Electric Coop, Inc to Camden County, Dallas County, Laclede County, Pulaski County, Webster County, Wright County in Missouri.
What backup battery or generator size is recommended for Laclede Electric Coop, Inc customers?
For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.
- Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
- Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
- Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
Our risk-free engineering & satisfaction guarantee
Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.