Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #10697 • Cooperative • MISO

Lake Country Power (MN) Outage & Grid Reliability

Customers served by Lake Country Power (Cooperative, 51,603 meters across 8 Minnesota county/counties) lost power an average of 6.9 hours per year (414.7 minutes across 2.32 outages/yr in 2025 federal EIA filings) — earning Reliability Grade BBB. Average residential electricity rate: 18.34¢/kWh.

EIA Outage Time (SAIDI)414.7 min/yr (6.9 hrs)
Reliability GradeGrade BBB
Customers Served51,603 Total
Avg Residential Rate18.34¢/kWh
Utility Reliability Summary (Lake Country Power): Customers served by Lake Country Power (Cooperative, 51,603 meters across 8 Minnesota county/counties) lost power an average of 6.9 hours per year (414.7 minutes across 2.32 outages/yr in 2025 federal EIA filings) — earning Reliability Grade BBB. Average residential electricity rate: 18.34¢/kWh.
Utility Reliability Field Brief • Lake Country Power (MN)

What Lake Country Power Outage Data Means for Customers

Lake Country Power is a cooperative in the MISO balancing authority, serving 51,603 customers: 47,386 residential, 4,214 commercial, and 3 industrial. The 2025 EIA Form 861 data shows SAIDI of 414.7 minutes a year with major events included and SAIFI of 2.32 outages a year. Without major events, SAIDI falls to 141.2 minutes. That gap of roughly 273 minutes is storm damage, the wind, ice, and falling trees that hit lines in places like Aitkin, Carlton, Cass, Itasca, Koochiking, and Lake counties. Divide minutes by interruptions and the average outage runs close to three hours. Averages hide the tail, and the long outages tend to land on the ends of rural lines. EP grades this utility BBB, moderate outage exposure in the 260 to 420 minute range. That is not alarming, but it is enough to plan around, especially with a residential rate of 18.34 cents per kWh.

Sizing Quiet Home Backup vs. Standby Power in MN

Start with what you cannot live without: furnace blower or boiler circulator, well pump, sump pump, refrigerator, a few lights, and your internet router. Add those running loads, then account for the starting surge of your largest motor, usually the well pump. Have a licensed electrician do the load calculation instead of guessing.

A battery system fits the typical outage of a few hours. It is quiet, needs no fuel, and can run indoors. Keep it in conditioned space, because Minnesota cold shrinks battery output. A standby generator fits the storm that takes lines down for days. It needs a permitted transfer switch, a propane or natural gas supply, and an outdoor location well away from windows and doors because of carbon monoxide. Never backfeed a house through a dryer outlet. That is how line workers get hurt.

If you run either one, test it monthly under real load. Most failures I see are stale fuel, dead starter batteries, and a transfer switch nobody has ever exercised.

What Local Shops, Clinics & Facilities on Lake Country Power Lines Should Do

Write down what has to stay running and for how long. For a shop, that is usually the walk-in cooler, point-of-sale, phones, and heat so pipes do not freeze. Put servers and network gear on a UPS so they ride through short blips, then let a generator carry the longer outages.

Clinics should treat medication refrigeration, oxygen equipment, and records access as the priority circuits, and should keep a written plan for what happens if power is out longer than the generator's fuel supply. Do not assume a generator alone covers it.

Municipal operators should look hardest at water wells, lift stations, and fire halls. Use an automatic transfer switch, a fuel contract with a delivery commitment, and an annual load test, not just a no-load run. Keep a one-page runbook so a night-shift operator can restart everything.

Finally, call the co-op and ask about outage history on your specific feeder. System averages are useful, but your feeder's record is what should size your backup.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)414.7 min/yr (6.9 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)2.32 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)178.7 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)141.2 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)51,603 (47,386 / 4,214 / 3)2025 EIA Form 861
Observed Residential Electricity Rate18.34¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • MISOU.S. EIA Form 861

2. Counties Served by Lake Country Power (8 Tracked in Minnesota)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Lake Country Power)

How reliable is Lake Country Power compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Lake Country Power logged 414.7 total outage minutes/year (SAIDI with Major Event Days) and 141.2 minutes/year excluding major storms (Moderate Outage Exposure (260–420 min/yr)).

What counties does Lake Country Power serve in Minnesota?

U.S. EIA Form 861 Service Territory records map Lake Country Power to Aitkin County, Carlton County, Cass County, Itasca County, Koochiching County, Lake County, Pine County, St. Louis County in Minnesota.

What backup battery or generator size is recommended for Lake Country Power customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power