Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #10599 • Cooperative • AECI

Lake Region Electric Coop, Inc - (OK) (OK) Outage & Grid Reliability

Customers served by Lake Region Electric Coop, Inc - (OK) (Cooperative, 26,736 meters across 7 Oklahoma county/counties) lost power an average of 5.3 hours per year (316.5 minutes across 1.5 outages/yr in 2025 federal EIA filings) — earning Reliability Grade BBB. Average residential electricity rate: 13.03¢/kWh.

EIA Outage Time (SAIDI)316.5 min/yr (5.3 hrs)
Reliability GradeGrade BBB
Customers Served26,736 Total
Avg Residential Rate13.03¢/kWh
Utility Reliability Summary (Lake Region Electric Coop, Inc - (OK)): Customers served by Lake Region Electric Coop, Inc - (OK) (Cooperative, 26,736 meters across 7 Oklahoma county/counties) lost power an average of 5.3 hours per year (316.5 minutes across 1.5 outages/yr in 2025 federal EIA filings) — earning Reliability Grade BBB. Average residential electricity rate: 13.03¢/kWh.
Utility Reliability Field Brief • Lake Region Electric Coop, Inc - (OK) (OK)

What Lake Region Electric Coop, Inc - (OK) Outage Data Means for Customers

Lake Region Electric Coop is a cooperative in the AECI balancing authority, serving 26,736 customers: 25,042 residential, 1,495 commercial and 199 industrial. Across Adair, Cherokee, Delaware, Mayes, Muskogee and Rogers counties, EIA Form 861 shows 316.5 minutes of interruption per customer per year with major events included, and 1.5 outages per year. That is about five and a quarter hours a year. Strip out major events and it drops to 107.7 minutes. So roughly 209 minutes of the total comes from big storms, not routine faults.

That split matters. Most years you will see short blips. Every so often you get a long ice or wind event that wipes out the average. EP grades the system BBB, moderate outage exposure, in the 260 to 420 minute band. Residential power averages 13.03 cents per kWh, so running a generator on fuel will cost you more per kWh than the grid. Buy backup for the bad day, not to save money.

Sizing Quiet Home Backup vs. Standby Power in OK

Start with what you cannot lose: the refrigerator, a few lights, internet, phone charging, a furnace blower or fans, and a well pump if you have one. Add up the running watts on each nameplate. Then find the starting surge on anything with a motor, because well pumps and air conditioners ask for far more at startup than they do running. Size to the surge, not the sticker.

For short, frequent interruptions, a battery system with an inverter is quiet and switches over without a hiccup. It covers the blips and the first few hours of a longer outage. Batteries run out, though. If your concern is a multi-day storm in rural country where crews have long roads to cover, a standby generator on propane or natural gas, with an automatic transfer switch, is the more dependable answer. A battery paired with a generator is a sound combination if the budget allows.

Never backfeed a panel through a dryer outlet. Use a proper transfer switch or interlock installed under permit. Keep portable generators well away from windows and doors, since carbon monoxide kills people every storm season. Look for U.S. EPA-certified units and run a test under load a few times a year.

What Local Shops, Clinics & Facilities on Lake Region Electric Coop, Inc - (OK) Lines Should Do

Treat 107.7 minutes as your normal and 316.5 as what a bad year can look like. Figure out what an outage costs you per hour: spoiled stock, lost sales, idle crews, missed appointments. Compare that with the installed cost of backup and you will know where to spend.

Put critical loads on a separate panel so the generator carries only what matters: refrigeration, point of sale, network gear, emergency lighting and key equipment. Use a UPS for servers and registers so they ride through the first few seconds while the generator starts. Clinics should keep refrigerated medications and any powered patient equipment on a tested backup circuit. Do not assume the generator is ready. Exercise it monthly, load-test it yearly, and keep fuel fresh.

Municipal operators should put water and wastewater pumps, lift stations, dispatch and warning sirens at the front of the line. Install transfer switches and quick-connect inlets so a rented generator can be hooked up fast. Write down which feeders serve which facilities and talk to the co-op about restoration priorities before the storm arrives. Industrial customers should ask about power quality as well as outages, since a blip can trip sensitive equipment.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)316.5 min/yr (5.3 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)1.5 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)210.7 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)107.7 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)26,736 (25,042 / 1,495 / 199)2025 EIA Form 861
Observed Residential Electricity Rate13.03¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • AECIU.S. EIA Form 861

2. Counties Served by Lake Region Electric Coop, Inc - (OK) (7 Tracked in Oklahoma)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Lake Region Electric Coop, Inc - (OK))

How reliable is Lake Region Electric Coop, Inc - (OK) compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Lake Region Electric Coop, Inc - (OK) logged 316.5 total outage minutes/year (SAIDI with Major Event Days) and 107.7 minutes/year excluding major storms (Moderate Outage Exposure (260–420 min/yr)).

What counties does Lake Region Electric Coop, Inc - (OK) serve in Oklahoma?

U.S. EIA Form 861 Service Territory records map Lake Region Electric Coop, Inc - (OK) to Adair County, Cherokee County, Delaware County, Mayes County, Muskogee County, Rogers County, Wagoner County in Oklahoma.

What backup battery or generator size is recommended for Lake Region Electric Coop, Inc - (OK) customers?

For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power