PacifiCorp (WA) Outage & Grid Reliability
Customers served by PacifiCorp (Investor Owned, 137,964 meters across 6 Washington county/counties) lost power an average of 1.7 hours per year (102.7 minutes across 0.56 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 14.33¢/kWh.
What PacifiCorp Outage Data Means for Customers
PacifiCorp is an investor-owned utility serving 137,964 Washington customers in the PACW balancing authority. That includes 114,998 residential, 17,570 commercial, and 5,396 industrial accounts across Benton, Columbia, Cowlitz, Garfield, Walla Walla, and Yakima counties. EIA Form 861 reports SAIDI of 102.7 minutes a year with major events and 58.0 without them, plus SAIFI of 0.56 outages a year. That earns an AA grade, meaning high reliability at or under 160 minutes a year.
Here is what that means at the kitchen table. The average customer sees an outage roughly once every two years. Divide 102.7 by 0.56 and a typical interruption runs around three hours. The roughly 45-minute gap between the two SAIDI figures comes from major events like big storms. Averages hide the tail, though. If you sit at the end of a long rural feeder, your experience can be well worse than the system number.
Sizing Quiet Home Backup vs. Standby Power in WA
Start with what you must keep running, not what you want. Refrigerator, furnace blower, a few lights, internet, medical devices, and a well pump if you have one. Add up running watts and starting surge for each. Motors, like well pumps and compressors, pull several times their running load for a moment, and that surge decides your sizing.
A battery system fits the outage this data describes: a few hours, quiet, no fuel. It handles essential circuits well. It will not carry whole-house air conditioning or electric heat through a long event, so do not ask it to. A standby generator on natural gas or propane suits long outages, rural properties, and heavy loads. Buy a unit that meets U.S. EPA emissions requirements, and site it away from windows and intakes because carbon monoxide kills people every year.
Either way, you need a properly permitted transfer switch installed by a licensed electrician. Never backfeed through a dryer outlet. At 14.33 cents per kWh, grid power is cheap, so backup is insurance, not savings. Size it for the outage you cannot afford, not the one you merely dislike.
What Local Shops, Clinics & Facilities on PacifiCorp Lines Should Do
Write down your critical loads and how long each can be dark. For a clinic, that is vaccine and medication refrigeration, IT, and lighting for safe patient movement. For a shop, it is the POS, the cooler, and the door locks. For a municipal operator, it is water pumping, wastewater lift stations, and dispatch.
Put those loads on a separate critical panel with an automatic transfer switch. Test it monthly under real load, not just idling. Most generator failures I see are dead starting batteries, stale fuel, and a closed fuel valve. Keep a log and a fuel plan.
Industrial and commercial accounts should remember that SAIDI and SAIFI count sustained outages. Momentary blinks and voltage sags can still trip drives and reset controls, so consider ride-through protection such as a UPS on sensitive equipment.
Finally, call PacifiCorp and ask for the outage history on your specific feeder. System averages are a starting point. Your feeder's record should drive your backup spending.
1. Official U.S. EIA Form 861 Reliability & Customer Record
| EIA Form 861 Metric | Observed Utility Value | Reporting Basis |
|---|---|---|
| SAIDI (Total Outage Minutes / Year) | 102.7 min/yr (1.7 hrs) | All Events w/ Major Event Days (2025) |
| SAIFI (Average Outages / Year) | 0.56 interruptions/yr | IEEE / Utility Standard w/ MED |
| CAIDI (Avg Restoration Minutes / Outage) | 183.4 min/outage | Average Customer Outage Duration |
| SAIDI (Blue-Sky / Excluding Major Storms) | 58 min/yr | Without Major Event Days |
| Total Customers (Res / Com / Ind) | 137,964 (114,998 / 17,570 / 5,396) | 2025 EIA Form 861 |
| Observed Residential Electricity Rate | 14.33¢/kWh | 2025 EIA Revenues / MWh |
| Ownership & Balancing Authority | Investor Owned • PACW | U.S. EIA Form 861 |
2. Counties Served by PacifiCorp (6 Tracked in Washington)
Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:
3. Frequently Asked Questions (PacifiCorp)
How reliable is PacifiCorp compared to other US utilities?
Under 2025 U.S. EIA Form 861 reporting, PacifiCorp logged 102.7 total outage minutes/year (SAIDI with Major Event Days) and 58 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).
What counties does PacifiCorp serve in Washington?
U.S. EIA Form 861 Service Territory records map PacifiCorp to Benton County, Columbia County, Cowlitz County, Garfield County, Walla Walla County, Yakima County in Washington.
What backup battery or generator size is recommended for PacifiCorp customers?
For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.
- Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
- Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
- Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
Our risk-free engineering & satisfaction guarantee
Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.