Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #14724 • Cooperative • TVA

Pennyrile Rural Electric Coop (KY) Outage & Grid Reliability

Customers served by Pennyrile Rural Electric Coop (Cooperative, 47,654 meters across 8 Kentucky county/counties) lost power an average of 16.4 hours per year (985.9 minutes across 4.32 outages/yr in 2025 federal EIA filings) — earning Reliability Grade B. Average residential electricity rate: 13.86¢/kWh.

EIA Outage Time (SAIDI)985.9 min/yr (16.4 hrs)
Reliability GradeGrade B
Customers Served47,654 Total
Avg Residential Rate13.86¢/kWh
Utility Reliability Summary (Pennyrile Rural Electric Coop): Customers served by Pennyrile Rural Electric Coop (Cooperative, 47,654 meters across 8 Kentucky county/counties) lost power an average of 16.4 hours per year (985.9 minutes across 4.32 outages/yr in 2025 federal EIA filings) — earning Reliability Grade B. Average residential electricity rate: 13.86¢/kWh.
Utility Reliability Field Brief • Pennyrile Rural Electric Coop (KY)

What Pennyrile Rural Electric Coop Outage Data Means for Customers

Pennyrile Rural Electric Coop is a cooperative serving 47,654 customers: 40,704 residential, 6,924 commercial, and 26 industrial. It buys within the TVA balancing authority, so bulk supply is handled upstream. What you feel at your meter is mostly the local distribution system: long rural feeders, trees, ice, wind, and aging hardware.

The 2025 EIA Form 861 numbers say SAIDI with major events is 985.9 minutes a year, about 16 hours. SAIFI is 4.32 outages a year. Take out major event days and SAIDI falls to 245.5 minutes, roughly four hours. About three quarters of your lost time comes from the big storms, while the rest is the steady drip of ordinary faults. EP grades this territory B, in the high outage duration band of 12 to 20 hours a year. Expect several interruptions annually across Butler, Christian, Grant, Livingston, Logan, and Muhlenberg Counties, plus the occasional multi-day event. At 13.86 cents per kWh residential, backup power is insurance against those events, not a way to save money.

Sizing Quiet Home Backup vs. Standby Power in KY

Start with how long you need to ride out an outage, then size to the loads. A battery and inverter system fits the common short outage. It runs the refrigerator, freezer, lights, internet, phone chargers, a furnace blower, and medical devices with no noise or exhaust. A standby generator on natural gas or propane, with an automatic transfer switch, fits the ice-storm week when the grid stays down and the battery would run flat.

Write down what you must keep running. Then find the biggest motors: well pump, heat pump, central air compressor. Their startup surge sizes the equipment more than their running draw does. If you can't carry everything, put those circuits on a critical-loads panel and leave the electric range and water heater off it.

Have a licensed electrician install the transfer equipment and pull permits. Never backfeed a house through a dryer outlet, because it can kill a lineman. Run portable generators outdoors, well away from doors and windows, and keep working carbon monoxide alarms in the house. Exercise any engine under load monthly, and keep fuel fresh or your supply line verified.

What Local Shops, Clinics & Facilities on Pennyrile Rural Electric Coop Lines Should Do

With SAIFI at 4.32, assume you will see repeated interruptions each year, and some will be short blinks. Those blinks can still reboot registers, servers, and lab equipment, so put a UPS on anything that hates a restart. Behind that, decide what really has to stay up: refrigeration, phones, point-of-sale, lighting at exits, medication storage, heating, and pumps.

Put those loads on a separate panel fed through a transfer switch, and size the generator to that panel instead of the whole building. Test it under real load, not just a no-load run. Log fuel on hand and know your resupply path before a regional storm, because everyone calls the same supplier at once.

Municipal operators should treat lift stations, water treatment, and dispatch or emergency operations as first priority, and verify transfer switches and fuel runtime every season. Keep a written restoration contact list.

Talk to the coop about which feeder serves you. Keep your own outage log with dates and durations, since it shows whether you are living on the 245.5-minute side of the data or the 985.9-minute side.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)985.9 min/yr (16.4 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)4.32 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)228.1 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)245.5 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)47,654 (40,704 / 6,924 / 26)2025 EIA Form 861
Observed Residential Electricity Rate13.86¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • TVAU.S. EIA Form 861

2. Counties Served by Pennyrile Rural Electric Coop (8 Tracked in Kentucky)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Pennyrile Rural Electric Coop)

How reliable is Pennyrile Rural Electric Coop compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Pennyrile Rural Electric Coop logged 985.9 total outage minutes/year (SAIDI with Major Event Days) and 245.5 minutes/year excluding major storms (High Outage Duration Territory (12–20 hrs/yr)).

What counties does Pennyrile Rural Electric Coop serve in Kentucky?

U.S. EIA Form 861 Service Territory records map Pennyrile Rural Electric Coop to Butler County, Christian County, Grant County, Livingston County, Logan County, Muhlenberg County, Todd County, Trigg County in Kentucky.

What backup battery or generator size is recommended for Pennyrile Rural Electric Coop customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

P.S. — The Short Answer (10-Second Takeaway):
  • Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
  • Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
  • Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
100% Money-Back & Zero-Obligation Guarantee

Our risk-free engineering & satisfaction guarantee

Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.

Free backup power & water sizer (60 sec) Size Backup Power