Potomac Electric Power Co (DC) Outage & Grid Reliability
Customers served by Potomac Electric Power Co (Investor Owned, 352,372 meters across 1 District of Columbia county/counties) lost power an average of 0.8 hours per year (50.3 minutes across 0.32 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AAA. Average residential electricity rate: 18.46¢/kWh.
What Potomac Electric Power Co Outage Data Means for Customers
Potomac Electric Power Co is an investor-owned utility in the PJM balancing authority. It serves 352,372 customers in the District of Columbia: 324,763 residential, 27,605 commercial, and 1 industrial. The 2025 EIA Form 861 shows SAIDI of 50.3 minutes per year with major events and 33.9 minutes without them. SAIFI is 0.32 outages per year.
In plain terms, the average customer loses power about once every three years. Dividing minutes by interruptions puts the typical outage a little over two and a half hours. The roughly 16-minute gap between the two SAIDI figures is what major storms add to the average. That earns an AAA grade, top-decile reliability at 90 minutes a year or less.
Averages hide the bad block, though. If your feeder is the one that trips, you get a 100 percent outage, not 50 minutes. At 18.46 cents per kWh residential, backup power is insurance, not a money-saver. Buy it for what an outage would cost you.
Sizing Quiet Home Backup vs. Standby Power in DC
Start with a list of what must stay on: refrigerator, router, phone chargers, a few lights, any medical equipment, a sump pump, the furnace blower. Add up the running watts, then check the startup surge on anything with a motor. Surge, not running load, is what trips undersized systems.
With outages this infrequent and this short, a battery system on a few essential circuits fits most DC homes. It is silent, makes no exhaust, and starts instantly. A natural gas or propane standby generator makes sense if you have a well pump, home medical needs, or a long-outage risk you cannot tolerate. It needs space, clearances, and a permit.
Rowhouses and condos rarely have room or permission for a generator, so read your lease or HOA rules first. Never run a portable generator in a garage, basement, or near a window. Carbon monoxide kills quietly. Have a licensed electrician install a transfer switch or interlock under permit, because backfeeding the grid endangers line crews. If you buy a generator, check that it meets current U.S. EPA emissions requirements.
What Local Shops, Clinics & Facilities on Potomac Electric Power Co Lines Should Do
Map your critical loads before you shop for equipment: point-of-sale, servers, phones, refrigeration, egress and emergency lighting, door access. Put IT gear on a UPS sized to ride through a switch and shut down cleanly. Put refrigeration and life-safety loads on a generator, or on a battery system sized for the realistic outage length, which is a few hours for most events.
Clinics and care facilities should put vaccine refrigeration and powered medical equipment on dedicated, labeled backup circuits and keep a written procedure for what happens in the first thirty minutes. Do not assume the grid's good numbers will cover you. A single feeder fault can still shut you down.
Municipal operators should treat pumping, traffic signals, radio, and shelter buildings as priority loads. Load-test generators on a schedule, not just run them idle. Rotate fuel, keep transfer switch procedures posted, and log every outage with a time stamp. Ask your utility account representative about your feeder's recent history. That record is worth more than the system-wide average when you decide what to spend.
1. Official U.S. EIA Form 861 Reliability & Customer Record
| EIA Form 861 Metric | Observed Utility Value | Reporting Basis |
|---|---|---|
| SAIDI (Total Outage Minutes / Year) | 50.3 min/yr (0.8 hrs) | All Events w/ Major Event Days (2025) |
| SAIFI (Average Outages / Year) | 0.32 interruptions/yr | IEEE / Utility Standard w/ MED |
| CAIDI (Avg Restoration Minutes / Outage) | 155.2 min/outage | Average Customer Outage Duration |
| SAIDI (Blue-Sky / Excluding Major Storms) | 33.9 min/yr | Without Major Event Days |
| Total Customers (Res / Com / Ind) | 352,372 (324,763 / 27,605 / 1) | 2025 EIA Form 861 |
| Observed Residential Electricity Rate | 18.46¢/kWh | 2025 EIA Revenues / MWh |
| Ownership & Balancing Authority | Investor Owned • PJM | U.S. EIA Form 861 |
2. Counties Served by Potomac Electric Power Co (1 Tracked in District of Columbia)
Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:
3. Frequently Asked Questions (Potomac Electric Power Co)
How reliable is Potomac Electric Power Co compared to other US utilities?
Under 2025 U.S. EIA Form 861 reporting, Potomac Electric Power Co logged 50.3 total outage minutes/year (SAIDI with Major Event Days) and 33.9 minutes/year excluding major storms (Top-Decile Grid Reliability (<=90 min/yr)).
What counties does Potomac Electric Power Co serve in District of Columbia?
U.S. EIA Form 861 Service Territory records map Potomac Electric Power Co to District of Columbia in District of Columbia.
What backup battery or generator size is recommended for Potomac Electric Power Co customers?
For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.
- Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
- Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
- Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
Our risk-free engineering & satisfaction guarantee
Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.