Rochester Gas & Electric Corp (NY) Outage & Grid Reliability
Customers served by Rochester Gas & Electric Corp (Investor Owned, 394,444 meters across 7 New York county/counties) lost power an average of 2.2 hours per year (132.8 minutes across 1.22 outages/yr in 2025 federal EIA filings) — earning Reliability Grade AA. Average residential electricity rate: 20.72¢/kWh.
What Rochester Gas & Electric Corp Outage Data Means for Customers
Rochester Gas & Electric is an investor-owned utility in the NYIS balancing authority, serving 394,444 customers: 353,617 residential, 40,218 commercial and 609 industrial. The territory covers Monroe, Genesee, Livingston, Ontario, Wayne and Allegany counties, among others. The 2025 EIA Form 861 shows SAIDI of 132.8 minutes a year with major events and 89.0 minutes without them. SAIFI is 1.22 outages per customer per year. That earns an EP Utility Grid Reliability Grade of AA, which means high reliability at 160 minutes a year or less.
In plain terms, the average customer loses power a bit more than once a year. Divide 132.8 by 1.22 and a typical interruption runs roughly 109 minutes. The 43.8-minute gap between the two SAIDI figures is storm damage. Averages hide the tails, though. A house at the end of a long rural lateral in Allegany or Wayne County will likely see worse than the number above, and a downtown feeder customer will see better. Plan for your own circuit, not the system average.
Sizing Quiet Home Backup vs. Standby Power in NY
Start by listing what you cannot lose: furnace blower and igniter, refrigerator, sump pump, well pump if you have one, router, medical equipment and a few lights. Read the nameplates and add up running watts, then check starting watts for anything with a motor, because pumps and compressors surge when they kick on.
With reliability this good, most outages are short, and a modest battery system covering those essentials is quiet, has no exhaust and does the job. Its limit is a multi-day winter storm, when you can only draw down the stored energy unless you have solar to recharge it. A natural gas or propane standby generator with an automatic transfer switch handles the long events. Hire a licensed electrician, pull the permit and site it away from windows and doors. Ask the installer about emissions compliance with U.S. EPA rules for that class of engine. Put a carbon monoxide alarm inside the house regardless.
If you run a portable unit, use a proper inlet and interlock. Never backfeed a panel through a dryer outlet, because that kills line crews. At a residential rate of 20.72 cents per kWh, grid power is cheap compared with generator fuel, so backup is for protection, not savings.
What Local Shops, Clinics & Facilities on Rochester Gas & Electric Corp Lines Should Do
Run a critical-load list before you buy anything. For a shop, that means refrigeration, point-of-sale, phones, network gear and egress lighting. For a clinic, add medication and vaccine refrigeration, oxygen concentrators and anything tied to patient safety, and confirm your code requirements with the local fire authority. Put servers and registers on a UPS so the generator has time to start and transfer.
Generators fail from neglect more than from age. Exercise them under real load on a schedule, keep fuel fresh, log every test and replace batteries before they fail. Exercise the transfer switch too, since that is the part people forget.
Municipal operators should rank loads by consequence: water pumping, lift stations, traffic signals, communications and warming or cooling shelters. Know which feeder each site sits on and ask the utility about critical-facility coordination. Industrial customers should look at voltage sags and momentary interruptions, which a SAIDI number does not capture but a production line certainly notices.
Write down your restoration plan, including who fuels, who tests and who calls. A good grade on paper does not keep your doors open.
1. Official U.S. EIA Form 861 Reliability & Customer Record
| EIA Form 861 Metric | Observed Utility Value | Reporting Basis |
|---|---|---|
| SAIDI (Total Outage Minutes / Year) | 132.8 min/yr (2.2 hrs) | All Events w/ Major Event Days (2025) |
| SAIFI (Average Outages / Year) | 1.22 interruptions/yr | IEEE / Utility Standard w/ MED |
| CAIDI (Avg Restoration Minutes / Outage) | 108.9 min/outage | Average Customer Outage Duration |
| SAIDI (Blue-Sky / Excluding Major Storms) | 89 min/yr | Without Major Event Days |
| Total Customers (Res / Com / Ind) | 394,444 (353,617 / 40,218 / 609) | 2025 EIA Form 861 |
| Observed Residential Electricity Rate | 20.72¢/kWh | 2025 EIA Revenues / MWh |
| Ownership & Balancing Authority | Investor Owned • NYIS | U.S. EIA Form 861 |
2. Counties Served by Rochester Gas & Electric Corp (7 Tracked in New York)
Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:
3. Frequently Asked Questions (Rochester Gas & Electric Corp)
How reliable is Rochester Gas & Electric Corp compared to other US utilities?
Under 2025 U.S. EIA Form 861 reporting, Rochester Gas & Electric Corp logged 132.8 total outage minutes/year (SAIDI with Major Event Days) and 89 minutes/year excluding major storms (High Grid Reliability (<=160 min/yr)).
What counties does Rochester Gas & Electric Corp serve in New York?
U.S. EIA Form 861 Service Territory records map Rochester Gas & Electric Corp to Allegany County, Genesee County, Livingston County, Monroe County, Ontario County, Wayne County, Wyoming County in New York.
What backup battery or generator size is recommended for Rochester Gas & Electric Corp customers?
For outages lasting 4 to 24+ hours, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.
- Check your local risk first: Open Right-Now Crisis Mode or inspect your county grade to lock in local NOAA radio MHz, pipe-freeze floors, and 24/7 hospitals.
- Fix your weakest link before a storm: Run our free 60-Second Home Blackout Stress Test or 13 sizing calculators before buying gear.
- Keep an offline paper copy: Click Print above to put a 1-page Lifeline Card on your fridge or facility wall before cell towers go dark.
Our risk-free engineering & satisfaction guarantee
Every interactive sizing calculator, county/ZIP hazard dossier, and local contractor quote match is 100% free with zero obligation, and every paid Continuity Binder or Institutional Kit is backed by a 30-day 100% unconditional money-back guarantee.