LIVE US PULSE: Loading NOAA NWS Alerts, DOE ODIN Outages, USGS Quakes & Wildfires...
Live Situation Room →
Emergency Preparedness
U.S. EIA Form 861 Utility Profile • Utility #19579 • Cooperative • SWPP

Upshur Rural Elec Coop Corp (TX) Outage & Grid Reliability

Upshur Rural Elec Coop Corp (U.S. EIA Utility #19579, Cooperative) serves 51,559 total customers across 10 county/counties in Texas (SWPP grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1332.1 outage minutes per year (22.2 hours, SAIDI with major events) across 5.6 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 12.71¢/kWh.

EIA Outage Time (SAIDI)1332.1 min/yr (22.2 hrs)
Reliability GradeGrade CCC
Customers Served51,559 Total
Avg Residential Rate12.71¢/kWh
Utility Reliability Summary (Upshur Rural Elec Coop Corp): Upshur Rural Elec Coop Corp (U.S. EIA Utility #19579, Cooperative) serves 51,559 total customers across 10 county/counties in Texas (SWPP grid). In official 2025 U.S. EIA Form 861 filings, customers experienced an average of 1332.1 outage minutes per year (22.2 hours, SAIDI with major events) across 5.6 interruptions/yr — earning an EP Utility Reliability Grade of CCC. Observed average residential rate: 12.71¢/kWh.
Utility Reliability Field Brief • Upshur Rural Elec Coop Corp (TX)

What Upshur Rural Elec Coop Corp Outage Data Means for Customers

Upshur Rural Elec Coop Corp is a cooperative serving 51,559 customers: 44,971 residential, 6,561 commercial, and 27 industrial. Power is balanced through SWPP, and the tracked territory includes Camp, Cass, Gregg, Harrison, Marion, and Morris counties. The 2025 EIA Form 861 numbers show 1332.1 minutes of outage per customer per year with major events counted, about 22 hours, across 5.6 interruptions. Take the major storms out and you still have 714.4 minutes, close to 12 hours. So this is not only a bad-storm problem. The lights go out often, and sometimes for a long time. The EP grade is CCC, severe multi-day outage territory, meaning over 20 hours a year.

Those are averages. A home near a substation may see far less, while a home at the end of a long rural tap through timber may see far more. Your residential rate of 12.71 cents per kWh is not high, so backup power will not save you money. It is insurance against food loss, frozen pipes, dry wells, and dead medical equipment.

Sizing Quiet Home Backup vs. Standby Power in TX

Start with a list of what must keep running: refrigerator, freezer, well pump, furnace blower or air conditioning, a few lights, internet, phone chargers, and any medical device. Add up running watts, then check the starting watts on motors. The well pump and the air conditioner compressor are what usually undersize a system.

With 5.6 interruptions a year, a battery and inverter system makes sense for short, frequent outages. It is quiet, has no fuel to haul, and switches over fast. A battery only lasts as long as its stored energy, though. For multi-day events, pair it with solar that can run while the grid is down, or with a generator.

A standby generator on natural gas or propane, wired through an automatic transfer switch, is the better answer for long outages. Propane means sizing the tank for days, not hours. Have a licensed electrician install a transfer switch or interlock. Never backfeed a house through a dryer outlet, because it can kill a lineman. Keep generators outdoors, well away from windows, and run a working carbon monoxide alarm inside. Test under real load monthly.

What Local Shops, Clinics & Facilities on Upshur Rural Elec Coop Corp Lines Should Do

Decide what has to stay up and put it on its own backed-up panel. For a shop, that is usually the point-of-sale system, network, lighting, and coolers. For a clinic, it is refrigerated medicine, phones, records, and exam-room power. A facility with water or wastewater pumps, dispatch, or fuel dispensing needs those loads at the top of the list.

Use an automatic transfer switch, exercise the generator on a schedule, and load-test it once a year. Keep fuel supply matched to a multi-day outage, since the grade says that is realistic here. Check state and U.S. EPA air rules before installing larger diesel units. Put a UPS on servers and registers to cover the gap before the generator picks up.

The 27 industrial members should look at ride-through for sensitive equipment, because 5.6 interruptions a year means 5.6 restarts. Every business and municipal operator should keep a written outage log with dates and durations, then take it to the co-op and ask about the reliability history of your specific feeder. It is your co-op, and that record is your leverage.

1. Official U.S. EIA Form 861 Reliability & Customer Record

EIA Form 861 MetricObserved Utility ValueReporting Basis
SAIDI (Total Outage Minutes / Year)1332.1 min/yr (22.2 hrs)All Events w/ Major Event Days (2025)
SAIFI (Average Outages / Year)5.6 interruptions/yrIEEE / Utility Standard w/ MED
CAIDI (Avg Restoration Minutes / Outage)238 min/outageAverage Customer Outage Duration
SAIDI (Blue-Sky / Excluding Major Storms)714.4 min/yrWithout Major Event Days
Total Customers (Res / Com / Ind)51,559 (44,971 / 6,561 / 27)2025 EIA Form 861
Observed Residential Electricity Rate12.71¢/kWh2025 EIA Revenues / MWh
Ownership & Balancing AuthorityCooperative • SWPPU.S. EIA Form 861

2. Counties Served by Upshur Rural Elec Coop Corp (10 Tracked in Texas)

Select your county below to view local FEMA disaster history, CMS 24/7 emergency hospitals, NOAA Weather Radio frequencies, and county Continuity Grades:

3. Frequently Asked Questions (Upshur Rural Elec Coop Corp)

How reliable is Upshur Rural Elec Coop Corp compared to other US utilities?

Under 2025 U.S. EIA Form 861 reporting, Upshur Rural Elec Coop Corp logged 1332.1 total outage minutes/year (SAIDI with Major Event Days) and 714.4 minutes/year excluding major storms (Severe Multi-Day Outage Territory (>20 hrs/yr)).

What counties does Upshur Rural Elec Coop Corp serve in Texas?

U.S. EIA Form 861 Service Territory records map Upshur Rural Elec Coop Corp to Camp County, Cass County, Gregg County, Harrison County, Marion County, Morris County, Rusk County, Smith County and 2 additional counties in Texas.

What backup battery or generator size is recommended for Upshur Rural Elec Coop Corp customers?

For outages lasting multi-day stretches during storms, homeowners should start with 7–14 kWh of quiet indoor LFP battery backup for refrigeration, Wi-Fi, and medical devices—or an 18–22 kW standby generator with a UL 1008 transfer switch for full HVAC/well loads.

Free backup power & water sizer (60 sec) Size Backup Power